Construction and Calibration of the NIST Large-Area-Source X-Ray Counting System

نویسندگان

  • J. M. R. Hutchinson
  • M. P. Unterweger
  • P. A. Hodge
چکیده

This paper describes the construction and calibration of the NIST large area x-ray counting system. 238Pu sources 8 in (20.32 cm) by 5 in (12.70 cm) thick, emitting L x rays in the range of 12-20 keV are calibrated for total emission rate and also for rate through a centrally located 3 in (7.63 cm) diameter aperture. Alpha particle emission rates are obtained using the known x-ray to alpha particle abundances. The sources will be used to calibrate alpha-particle surface monitors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NIST Virtual Gamma Spectrometry System: A Comparison of Counting Efficiencies from Measurements and Monte Carlo Simulations

Anthropometric and anthropomorphic phantoms have been used extensively for characterizing in-vivo measurement systems that determines internally deposited radionuclides. The accuracy in activity determination relies critically on system design, calibration routine, and reproducbility in material composition, geometry configuration, and physical dimensions of the phantoms respect to the actual o...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

Revision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.

After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NI...

متن کامل

Operation of NIST Josephson Array Voltage Standards

This paper begins with a brief discussion of the physical principles and history of Josephson effect voltage standards. The main body of the paper deals with the practical details of the array design, cryoprobe construction, bias source requirements, adjustment of the system for optimum performance, calibration algorithms, and an assessment of error sources for the NIST-developed Josephson arra...

متن کامل

Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray referenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 1991