One Thousand Dollar Assist Heart Pump for Patients from Developing Countries
نویسنده
چکیده
In spite of continuous improvements in device design and applications, the profound use of heart pump has been limited because of its high price. The available clinically applied heart pump costs mostly about 100 thousands US Dollars. The author has since long tried to develop a heart pump costing only 1000 Dollars for recovery or bridge to heart transplantation therapies. The device is a radially driven centrifugal pump with a brush-less DC motor and a streamlined impeller. Its bearing is rolling bearing using 4 to 6 needles, manufactured by special wear-proof polythene with super-high-molecular weight, thus the service life achieves more than 10 years. To avoid thrombus formation, a special purge system is introduced to the bearing, allowing the saline with heparin to be infused through the bearing into the pump. The bearing, therefore, keeps working in the saline, and absolutely no thrombus will be formed along the bearing. Animal experiments demonstrated that a 30 mL fluid infusion per hour is enough to prevent thrombus formation. With these improvements, the impeller pump has continuously run for 14 months in the laboratory, and no bearing wear can be measured. The device, weighing 150 g, is fully implantable, consumes approximately 9.6 W, delivers a 9Lmin-1 blood flow against a 120 mmHg mean pressure, and reaches a highest total efficiency of 24.7% for the motor (including the controller) and the pump. The device has been used in animal experiments together with an American artificial lung for more than one month in the University of Texas and also in human trials in the Taiwan University.
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملLeft Ventricular Heart Assist Device using MC and ECG Feedback
The human heart pumps blood throughout the body via the circulatory system, supplying oxygen and nutrients to the tissues which helps bodies function and removing carbon dioxide and other waste products [1]. Cardiac failure happens when the heart cannot pump enough blood and oxygen to support other organs [2]. In USA about 5.7 million adult patients are diagnosed with heart failure and one in 9...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2007