Detecting the Photon-Photon Interaction by Colliding Laser Beam Interferometry
نویسنده
چکیده
The feasibility of detecting the photon-photon interaction using Fabry-Perot type laser interferometers developed for gravity wave detection is demonstrated. An “external” laser beam, serving as a refractive medium, is alternatively fed into the cavities of the interferometer and made to collide with the “internal” beams thereby inducing a measurable phase difference between them. [hep-ph/9308293] PACS numbers: 12.20.Fv, 12.20.Ds, 14.80.Am, 07.60.Ly Typeset using REVTEX
منابع مشابه
Micro-channels over the glass surface made by interaction of Ar+ laser beam and Ag+/Na+ ion-exchanged glasses
Micro-channels are made over the Ag+/Na+ ion-exchanged soda-lime glass surface by interaction of an intense Ar+ laser beam and the silver ions inside the glass matrix. The Ar+ laser beam reduces the Ag+ ions inside the matrix. The Ag+ atoms aggregate into silver nano-clusters around the interaction area, inside the glass matrix. Aggregation of the silver atoms and the thermal effects of the int...
متن کاملThe radioisotope 67Ga (T 1/2 = 78 h) in extensively used as single photon marker for detecting the presence [Persian]
The radioisotope 67Ga (T 1/2 = 78 h) in extensively used as single photon marker for detecting the presence of malignancy and the diagnosis of inflammatory diseases. The high tumor specificity of carrier-free 67Ga make it one of the most interesting radionuclides in nuclear medicine for in vivo scanning studies. 67Ga is a cyclotron produced radioisotopes and is one of the radiopharmaceuti...
متن کاملارزیابی آلودگی فوتونی اپلیکاتور Beam Shaper با استفاده از شبیه سازی مونت کارلو
Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...
متن کاملPhoton Acceleration as the Laser Wakefield Diagnostic for Future Plasma Accelerators
In the near future, laser-plasma particle accelerators will be able to sustain electric fields in excess of 100 GeV/m, along plasma channels several Rayleigh lengths long. For these extreme conditions, present day laser wakefield diagnostics such as Frequency Domain Interferometry will not be able to resolve the wake field structure and determine the magnitude of the electric field. In this pap...
متن کاملMeasuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry
Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...
متن کامل