Effects of acute exposure to WIFI signals (2.45GHz) on heart variability and blood pressure in Albinos rabbit.
نویسندگان
چکیده
Electrocardiogram and arterial pressure measurements were studied under acute exposures to WIFI (2.45GHz) during one hour in adult male rabbits. Antennas of WIFI were placed at 25cm at the right side near the heart. Acute exposure of rabbits to WIFI increased heart frequency (+22%) and arterial blood pressure (+14%). Moreover, analysis of ECG revealed that WIFI induced a combined increase of PR and QT intervals. By contrast, the same exposure failed to alter maximum amplitude and P waves. After intravenously injection of dopamine (0.50ml/kg) and epinephrine (0.50ml/kg) under acute exposure to RF we found that, WIFI alter catecholamines (dopamine, epinephrine) action on heart variability and blood pressure compared to control. These results suggest for the first time, as far as we know, that exposure to WIFI affect heart rhythm, blood pressure, and catecholamines efficacy on cardiovascular system; indicating that radiofrequency can act directly and/or indirectly on cardiovascular system.
منابع مشابه
Blood and tissue levels of diazinon in rabbit following a subacute dermal exposure to incremental doses
BACKGROUND:Uncontrolled application of diazinon (DZN)can cause environmental contamination and adverse healtheffects on humans or animals. OBJECTIVES:This study aimed toinvestigate the toxic effects and the level of DZN in serum andtissues of rabbits following a sub acute dermal exposure totoxicant. METHODS:Different doses of DZN were applied dailyto New Zealand rabbits through the ear skin in ...
متن کاملHypotensive effect of Achillea wilhelmsii aqueous-ethanolic extract in rabbit
Objective: For many years in herbal medicine the antihypertensive and lowering blood lipid properties of Achillea wilhelmsii (A. wilhelmsii) have been suggested. In the present study the impacts of the plant extract on rabbit’s blood pressure and heart rate have been investigated. Materials and Methods: Twelve NWZ rabbits weighed 2-3 kg were randomly divided into two groups of 6 rabbits. The t...
متن کاملبررسی تأثیر استفاده از وسایل فردی حفاظت شنوایی در محیط پرسروصدا برروی فشارخون وضربان قلب
Abstract Background: Noise, as the most common industrial hazard, besides hearing loss may have adverse effects on other body systems. Many studies have demonstrated the adverse effects of noise on the cardiovascular system. Using personal protective devices is one of the methods for reducing noise exposure. Controlling noise exposure by means of personal protective devices theoretically reduc...
متن کاملAlterations in the vascular β-adrenoceptors of the rabbit knee joint due to acute inflammation
It has been shown that acute inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow. To investigate the role of vascular β- adrenoceptors in this event, 12 NZW rabbits were maintained anaesthetized by 1 % halothane in N2O/O2, and acute knee joint inflammation was induced by intra-articular injection of 1 ml of 2% carageenan solution 24 hours be...
متن کاملInvestigation of Response to Angiotensin (Ang ) and its Receptor Subtypes in Acutely Inflamed Joint Blood Vessels in Rabbit
Introduction: Inflammatory joint diseases are common in elderly, and regulation of joint blood flow (JBF) is important in these conditions. The aim of this study was to investigate the response of inflamed joint blood vessels to angiotensin (Ang ), a vasoconstrictor factor which has been shown to be produced in inflamed joints locally. Identification of Ang receptor subtypes in joint blood ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Environmental toxicology and pharmacology
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2015