Detection of Ni2+ by a dimethylglyoxime probe using attenuated total-reflection infrared spectroscopy.
نویسندگان
چکیده
A new analytical approach for the detection of Ni2+ utilizing an attenuated total reflection (ATR) technique is discussed in this paper. Nickel detection was accomplished on a silicon ATR parallelogram crystal uniformly coated by a ca. 1.5-microm Nafion film embedded with dimethylglyoxime (DMG) probe molecules. The detection of Ni2+ is based on the appearance of a unique infrared absorption peak at 1572 cm(-1) that corresponds to the C=N stretching mode in the nickel dimethylglyoximate, Ni(DMG)2, complex. The suitable operational pH range for the nickel infrared sensor is between 6 - 8. High alkalinity in the sample solution causes a leaching of Ni(DMG)2. The detection limit of the nickel infrared sensor is 1 ppm in a sample solution of pH = 8. Interference studies revealed that Cu2+ could compete with Ni2+ for the DMG sites in the Nafion matrix. The new nickel detection methodology can be potentially utilized, after further improvement, in field analysis to locate hot spots contaminated with a high ppm of Ni2+.
منابع مشابه
Surface-modified ZnSe waveguides for label-free infrared attenuated total reflection detection of DNA hybridization.
This communication presents a novel label-free biosensing method to monitor DNA hybridization via infrared attenuated total reflection (IR-ATR) spectroscopy using surface-modified ZnSe waveguides. Well-defined carboxyl-terminated monolayers were formed at H-terminated ZnSe by direct photochemical activation. Chemical activation of the acidic function was obtained by using succinimide/carbodiimi...
متن کاملComplexation-Based Detection of Nickel(II) at a Graphene-Chelate Probe in the Presence of Cobalt and Zinc by Adsorptive Stripping Voltammetry
The adsorptive stripping voltammetric detection of nickel and cobalt in water samples at metal film electrodes has been extensively studied. In this work, a novel, environmentally friendly, metal-free electrochemical probe was constructed for the ultra-trace determination of Ni2+ in water samples by Adsorptive Cathodic Stripping Voltammetry (AdCSV). The electrochemical platform is based on the ...
متن کاملIn situ monitoring of the DNA hybridization by attenuated total reflection surface-enhanced infrared absorption spectroscopy.
In situ monitoring of DNA hybridization kinetics is achieved via an attenuated total reflection surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS) technique using a sandwich assay structure. The synergistic enhancement effect gives this ATR-SEIRAS-based detection strategy promise to be a convenient and unique platform for bioanalysis.
متن کاملSolid Phase Extraction of Ultra Trace Amounts of Ni2+ by Dimethylglyoxime (DMG) Immobilized on Column
A column of alumina modified with sodium dodecyl sulfate (SDS) and dimethylglyoxime (DMG) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (FAAS) determinations. Under optimized conditions (pH=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. The nickel collected on the column was eluted with 5 mL of 1 M nitric ac...
متن کاملPH-dependent coordination of metal-lisinopril complex investigated by attenuated total reflection/Fourier transform infrared spectroscopy.
In order to simulate the in vivo binding behavior of angiotensin-converting enzyme (ACE) inhibitors to the zinc-containing active center of ACE, the in vitro interaction between lisinopril and zinc or nickel ions was investigated in aqueous solutions of different pH by using attenuated total reflection (ATR)/Fourier transform infrared (FT-IR) spectroscopy with second-derivative IR spectral anal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 18 4 شماره
صفحات -
تاریخ انتشار 2002