Ion Activity Scales for Use with Selective Ion-sensitive Electrodes

نویسنده

  • ROGER G. BATES
چکیده

The development of a variety of selective ion-sensitive electrodes focuses attention on numerical scales for the activity of individual ionic species, for these electrodes measure the activity of the selected ion only relative to that of the same species in a reference solution of known or assigned ion activity. Nevertheless, scales of ion activity must be based on a convention from outside the realm of thermodynamics. Scales based on different conventions are discussed and compared. In dilute solutions of ionic strength less than 0.1, several reasonable conventions give equivalent results, but the situation is more complex in concentrated solutions where the specific properties of the individual ionic species must be taken into consideration. It is shown that a convention based on the hydration number of each ionic species makes allowance for these individual differences. The scales of ionic activity so derived are found to be consistent with the responses of ion-selective electrodes. INTRODUCTION. POTENTIOMETRY As an analytical tool, modern potentiometry has its roots in investigations of the behaviour of electrodes and electrolyte solutions extending back in time to the nineteenth century1' 2 Electrodes for silver and mercury were used with success to indicate attainment of the equivalence point in titrations as early as 1893. Potentiometry was nurtured by the early work of Bjerrum4 and received strong impetus from the definition of a practical pH scale by Sørensen5 in t909. As time went on, electrodes suitable for the accurate measurement of the concentrations or activities of ions other than hydrogen— silver, cadmium, lead, zinc, the halides, sulphate—were applied to the solution of analytical problems. Nevertheless, the development of a practical pH glass electrode more than 40 years ago6 brought potentiometry out of the laboratory and put it to work guarding the quality of manufactured products, in controlling industrial processes, and in diagnosing illness. In the past decade, potentiometry has come into its own, as numerous types of ion-selective electrodes, responsive to anions as well as to cations, have become available. The impact of this technique of analytical measurement is enormous. It may fairly be said, however, that developments in the technology of ion-selective electrodes have outdistanced our efforts to understand and give precise meaning to the numbers these valuable new tools make available to us.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol

Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Potassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives

Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007