چکیده

Practical aspects of design and application radio frequency (RF) transformers in an ultrasonic system excitation channel are analysed. Design steps are discussed for those willing to design their own transformer an for excitation channel. Investigation has been carried out on what generator parameters can be obtained if instead of a purely active output stage the impedance matching RF transformer is used. It is assumed that a low output impedance active stage is coupled to a relatively high impedance ultrasonic transducer. An air coupled ultrasonic transducer has been used as a reference for the calculations. Several materials are considered for the RF transformer core and possible candidates and their properties for 10kHz to 10MHz frequency range are listed. The algorithm for performance investigation using only manufacturer parameters and the Matlab modeling has been presented. The experimental study has confirmed RF transformer suitability as a voltage step-up component for ultrasonic transducer excitation. The 0.1…10 MHz passband is achieved. The results obtained at different transmitted power levels (from 50W to 0.5W) indicate there is only slight reduction in the bandwidth. The presented configuration can be used for ultrasonic transducer excitation using an arbitrary waveform generator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Ultrasound Working Parameters on the Ultrasonic Power Density Some Neglected Problems in the Application of Ultrasound Bath

Ultrasound has been widely employed in food industry, while some of its working parameters are usually neglected to be described in its application, which caused the difficulty of reproducing and comparing the results obtained by different groups. So it is definitely not sufficient to simply state the ultrasound conditions such as ultrasound power, frequency and t...

متن کامل

An overview of therapeutic applications of ultrasound based on synergetic effects with gold nanoparticles and laser excitation

Acoustic cavitation which occurs at high intensities of ultrasound waves can be fatal for tumor cells. The existence of dissolved gases and also the presence of nanoparticles (NPs) in a liquid, irradiated by ultrasound, decrease the acoustic cavitation onset threshold and the resulting bubbles collapse. On the other hand, due to unique capabilities and optical properties of gold nanoparticles (...

متن کامل

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Application of Artificial Intelligent Approaches for the Efficiency and Energy Consumption of a Novel Sonocatalyst

The sonocatalytic activity of nano-sized ZnO powder was studied via the degradation of the Direct Blue 71 azo dye. The nano-sized ZnO powder that was selected was the same as that which was synthesized and characterized in our previous study. The influences of six operational parameters including the initial pH, the initial concentration, the dose of sonocatalyst, the ultrasound frequency, the ...

متن کامل

Initial Operation of the Ucla Plane Wave Transformer (pwt) Linac

We report on the initial operation of a novel compact rf linac — the plane wave transformer (PWT). The PWT is a 42 cm long, 8 cell standing-wave structure, operated at Sband, in a π−mode. We present the properties of this linac at rf power levels from 4 MW to 8 MW and beam energy from 7 MeV to 10 MeV, measured initially using both dark current and photo-electrons. Some technical issues associat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006