Influence of mitral valve morphology on double-balloon catheter balloon valvuloplasty in patients with mitral stenosis. Analysis of factors predicting immediate and 3-month results.

نویسندگان

  • C L Reid
  • P A Chandraratna
  • D T Kawanishi
  • A Kotlewski
  • S H Rahimtoola
چکیده

To determine if mitral valve morphology influences the results of double-balloon catheter balloon valvuloplasty (CBV) for mitral stenosis, two-dimensional echocardiography was performed in 33 patients before CBV. The two-dimensional echocardiographic features of leaflet motion, leaflet thickness, subvalvular disease, and commissural calcium and 14 pre-CBV clinical and hemodynamic variables were then correlated to the immediately post-CBV mitral valve area (MVA). At 3 months after CBV, the two-dimensional echocardiographic features of patients with a 25% or greater decrease in MVA were analyzed to determine whether mitral valve morphology had influenced early results. Leaflet motion had a significant relation with the immediately post-CBV MVA (r = 0.67, y = 4.5x + 0.29, and SEE = 0.45). Leaflet thickness had a weak and negative relation (r = -0.48, y = -0.17x + 2.6, and SEE = 0.53) with the immediately post-CBV MVA. Subvalvular disease and commissural calcium had no significant relation to the immediately post-CBV MVA. When leaflet motion and leaflet thickness were considered as grades of mild, moderate, and severe and assigned a score of 0-2, patients with more severe disease (total score, 3 or 4) had a significant lower MVA immediately after CBV (1.4 +/- 0.4 cm2) than patients with moderate disease (score, 1-2; MVA, 2.0 +/- 0.5 cm2; p less than 0.05) or mild disease (score, 0; MVA, 2.6 +/- 0.6 cm2; p less than 0.05). In 96% of patients with a total score of 0-2, the immediately post-CBV MVA was more than 1.4 cm2, whereas only 29% of patients with a total score of 3-4 had an immediately post-CBV MVA of more than 1.4 cm2. Analysis of all two-dimensional echocardiographic features showed that leaflet motion score had the strongest influence on the post-CBV MVA (p less than 0.001). When all two-dimensional echocardiographic, clinical, and hemodynamic variables were included, leaflet motion, effective balloon dilating area, and cardiac output were the strongest predictors of the immediate post-CB MVA.(ABSTRACT TRUNCATED AT 400 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate Results of Percutaneous Mitral Balloon Valvuloplasty in Patients with Mitral Stenosis

Introduction: Mitral stenosis is a prevalent valvular disease in developing countries. Percutaneous mitral balloon valvuloplasty (PMBV) is the gold standard treatment. The main objective of this study was to assess the initial results of PMBV in patients with mitral stenosis during 16 years (2002-2018) in Mashhad, Iran. Materials and Methods: From April 2002 to March 2018, 770 patients underwen...

متن کامل

SHORT TERM CLINICAL OUTCOME OF PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY VERSUS SURGICAL CLOSED MITRAL COMMISSUROTOMY

BaIlon mitral valvuloplasty and closed mitral valve conunissurotomy were performed in 450 and 127 patients, respectively. Also, 254 patients with severe mitral stenosis were enrolled in a prospective randomized trial comparing the two procedures. Immediately after balloon mitral valvuloplasty, mean left atrial pressure was 11.38±3.54 mmHg, transmitral valve gradient was 1.8±2 mmHg, and mit...

متن کامل

Influence of Mitral Valve Morphology on Double - Balloon Catheter Balloon Valvuloplasty in Patients With Mitral Stenosis

To determine if mitral valve morphology influences the results of double-balloon catheter balloon valvuloplasty (CBV) for mitral stenosis, two-dimensional echocardiography was performed in 33 patients before CBV. The two-dimensional echocardiographic features of leaflet motion, leaflet thickness, subvalvular disease, and commissural calcium and 14 pre-CBV clinical and hemodynamic variables were...

متن کامل

بررسی عوامل موثر در افزایش سطح دریچه و پیدایش نارسایی میترال بعد از بالون میترال والولوپلاستی در 110 بیمار در مجتمع بیمارستانی امام خمینی

Background: Percutaneous Transeptal Mitral Commisurotomy (PTMC) has been used in treating mitral stenosis with variable success, its main complication being mitral incompetence. There is a need to define the subgroup of the patients who benefit mostly from the procedure. Methods: We studied 110 patients (age 17 to 60 years mean 33.2) with mitral stenosis. PTMC was performed though femoral vein....

متن کامل

New technique for challenging cases of percutaneous balloon mitral valvuloplasty: The venoarterial looping

Mitral stenosis (MS) is generally the sequel of rheumatic carditis occurring in childhood (1). MS is particularly observed in developing countries (1, 2). Untreated patients can develop irreversible right ventricular failure (1, 2). Since its introduction by Inoue, percutaneous mitral balloon valvuloplasty (PMBV) is considered the leading and effective treatment option for symptomatic moderate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 1989