Reliability, repeatability, and reproducibility of pulmonary transit time assessment by contrast enhanced echocardiography

نویسندگان

  • Ingeborg H. F. Herold
  • Salvatore Saporito
  • R. Arthur Bouwman
  • Patrick Houthuizen
  • Hans C. van Assen
  • Massimo Mischi
  • Hendrikus H. M. Korsten
چکیده

BACKGROUND The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. METHODS Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. RESULTS Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. CONCLUSIONS PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hallowell, Gayle D. and Potter, Timothy J. and Bowen, I. Mark (2012) Reliability of quantitative echocardiography

Background: Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adu...

متن کامل

Reliability of quantitative echocardiography in adult sheep and goats

BACKGROUND Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adul...

متن کامل

Diffuse Pulmonary Arteriovenous Malformation in Children: Essential Value of Contrast Echocardiography in Diagnosis

Pulmonary arteriovenous malformations (PAVM) are abnormal communications between pulmonary arteries and pulmonary veins, and most commonly congenital in nature. Although rare, it is an important consideration in cyanotic patients of unknown cause. We report 3 cases with diffuse PAVM in children with different clinical manifestations and initial diagnosis was made by transthoracic contrast echoc...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Reproducibility of functional aortic analysis using MRI: the multi-ethnic study of atherosclerosis

Methods Twenty-five participants underwent aortic MRI twice over 13 ± 7 days. All aortic variables (ascending aortic area, descending aortic area, ascending and descending aortic strain [maximum area minus minimum area divided by minimum area], aortic arch transit time and pulse wave velocity [PWV]) from baseline and repeat MR were analyzed using a semi-automated method by the ARTFUN software. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015