Predicting the severity of fetal anemia using time-domain measurement of volume flow in the fetal aorta.
نویسندگان
چکیده
OBJECTIVES To assess the value of fetal aortic time-domain measurement of volume flow (using color velocity imaging quantification (CVI-Q)) in predicting the severity of fetal anemia. METHODS This was a prospective observational study, in which 24 pregnant women with suspected fetal anemia due to rising anti-red blood cell antibody titers underwent cordocentesis. The fetal aortic time-domain volume flow was measured before fetal blood sampling for fetal hemoglobin investigation. We examined the correlation between increased fetal aortic time-domain volume flow (>2 SD for gestational age) and fetal anemia (hemoglobin level <2 SD for gestational age). RESULTS Seventeen fetuses had anemia, and seven had normal hemoglobin. There was a strong correlation between the increase in fetal aortic time-domain volume flow and the drop in hemoglobin value (r = 0.81; P < 0.01). The sensitivity of this technique to predict fetal anemia was 81.3% and the specificity was 71.4%. The mean increase over time in aortic CVI-Q in anemic fetuses was 323.2 mL/min (95% CI, 200.1 to 446.4) compared with 86.9 mL/min (95% CI, -17.7 to 191.5) in the non-anemic group (P = 0.004). CONCLUSION Fetal aortic time-domain measurement of volume flow is significantly increased in cases of fetal anemia due to red-cell alloimmunization. These findings can be used to improve the sensitivity, specificity and positive predictive value of the non-invasive techniques used to predict fetal anemia, and may help in the selection of pregnancies that require cordocentesis and transfusion.
منابع مشابه
I-46: Obstetrical Doppler
Accurate assessment of gestational age, fetal growth, and the detection of fetal and placental abnormalities are major benefits of sonography. Color Doppler can be used to assist in the identification of vascular architecture, detection of vascular pathology and visualization of blood flow changes associated with physiologic processes and disease states. The clinical applications of obstetrical...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملThe Assessment of Feto-Maternal Hemorrhage in an Artificial Model Using Anti-D and Anti-Fetal Hemoglobin Antibody by Flow Cytometry
Background: When fetal red cells enter the maternal circulation from placenta, an event would be happened that is described as feto-maternal hemorrhage (FMH). This life-threatening condition could be detected by using RBC antigens (surface antigens and intracellular antigens). Therefore, the measurement of fetal RBC in an artificial model would be useful to calculate FMH and consequently the do...
متن کاملFetal RHD Genotyping Using Real-Time Polymerase Chain Reaction Analysis of Cell-Free Fetal DNA in Pregnancy of RhD Negative Women in South of Iran
Objective Maternal-fetal RhD antigen incompatibility causes approximately 50% of clinically significant alloimmunization cases. The routine use of prophylactic anti-D immunoglobulin has dramatically reduced hemolytic disease of the fetus and newborn. Recently, fetal RHD genotyping in RhD negative pregnant women has been suggested for appropriate use of anti-D immunoglobulin antenatal prophylaxi...
متن کاملPrediction of Fetal Acidosis by Blood Flow Velocity Waveform of the Fetal Descending Thoracic Aorta
=AbstractZFetal descending thoracic aorta blood flow velocity waveforms were measured in 63 pregnancies. They were either delivered by elective CIS before labor (56 patients) or suffered an antefartum fetal death (7 patients). There was a significant correlation between the aorta waveforms and the cord arterial pH. A cord arterial pH less than 7.20 or an intrauterine fetal death were used as ou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
دوره 23 5 شماره
صفحات -
تاریخ انتشار 2004