Load 1 Load 2 Load N Power Source Analog Preprocessing A / D Conversion
نویسنده
چکیده
At any point in the life of a building, mechanical and electrical equipment – the services infrastructure – may be poorly operated. Equipment may be inadvertently left in operation when not needed: lights and fans running all night or air conditioning in unoccupied spaces. Or equipment may be operated in ignorance of the cost, a problem exacerbated by time-varying electrical rates. Further, as buildings age, both the equipment and the building façade or envelope – a part of the construction infrastructure – wear, cease to function properly, and eventually fail, via myriad processes that are often undetected. Valves do not close fully, dampers stick, refrigerant leaks, heating and cooling coils – from the smallest refrigerator to the largest building air-conditioning system – become fouled with accumulated dirt and debris, and belts slip.
منابع مشابه
Compensation of Voltage and Current Harmonics in Hybrid Renewable Energy System Using Coordinated Power Control of RES Inverter
In this paper, an adaptive control strategy is proposed for the inverters of renewable energy source (RES) to simultaneously control the load voltage, grid current and the amount of instantaneous injected power to the grid in the presence of grid voltage distortions and nonlinearity of load current. In the proposed control strategy, the power quality of the local load can be settled based on th...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Robust Discrete FuzzyP+FuzzyI+FuzzyD Load Frequency Controller for Multi-Source Power System in Restructuring Environment
In this paper a fuzzy logic (FL) based load frequency controller (LFC) called discrete FuzzyP+FuzzyI+FuzzyD (FP+FI+FD) is proposed to ensure the stability of a multi-source power system in restructured environment. The whale optimization algorithm (WOA) is used for optimum designing the proposed control strategy to reduce fuzzy system effort and achieve the best performance of LFC task. Further...
متن کاملDesign and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملResidential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature
Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each para...