Assessment of pulmonary perfusion with breath-hold and free-breathing dynamic contrast-enhanced magnetic resonance imaging: quantification and reproducibility.

نویسندگان

  • Michael Ingrisch
  • Daniel Maxien
  • Felix Schwab
  • Maximilian F Reiser
  • Konstantin Nikolaou
  • Olaf Dietrich
چکیده

OBJECTIVES The purpose of this study was to investigate whether quantification of pulmonary perfusion from dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) yields more reproducible results with data acquired during free breathing than with data from conventional breath-hold measurements. MATERIAL AND METHODS Ten healthy male volunteers underwent 2 imaging sessions at a clinical 1.5-T MRI system, separated by a week±1 day. Each of these sessions comprised 2 DCE MRI acquisitions: one performed during breath-hold and one during free, shallow breathing; both acquisitions were separated by at least 20 minutes. For all DCE MRI measurements, a standard dose of gadobutrol was used. Breath-hold measurements lasted 53 seconds; free-breathing acquisitions were performed in a total acquisition time of 146 seconds.Lung tissue was segmented automatically to minimize user influence, and pulmonary plasma flow (PPF) and volume (PPV) were quantified on a per-pixel basis with a 1-compartment model. Free-breathing measurements were analyzed twice, (a) including data from the entire acquisition duration and (b) after truncation to the duration of the breath-hold measurements. For further statistical analysis, median values of the resulting parameter maps were determined. To assess intraindividual reproducibility, intraclass correlation coefficients and coefficients of variation between the first and second measurements were calculated for breath-hold, truncated, and full free-breathing measurements, respectively. Differences in the coefficients of variation were assessed with a nonparametric 2-sided paired Wilcoxon signed rank test. RESULTS All 40 measurements were completed successfully. Maps of PPF and PPV could be calculated from both measurement techniques; PPF and PPV in the breath-hold measurements were significantly lower (P < 0.001) than in truncated and full free-breathing measurements. Both evaluations of the free-breathing measurements yielded higher intraclass correlation coefficients and lower coefficients of variation between the first and second measurements than the breath-hold measurements. CONCLUSIONS Besides offering substantially higher patient comfort, free-breathing DCE MRI acquisitions allow for pixelwise quantification of pulmonary perfusion and hence generation of parameter maps. Moreover, quantitative perfusion estimates derived from free-breathing DCE MRI measurements have better reproducibility than estimates from the conventionally used breath-hold measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Free-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration.

OBJECTIVES The goal of this study was to develop free-breathing high-spatiotemporal resolution dynamic contrast-enhanced liver magnetic resonance imaging using non-Cartesian parallel imaging acceleration, and quantitative liver perfusion mapping. MATERIALS AND METHODS This study was approved by the local institutional review board and written informed consent was obtained from all participant...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Comparison of the quantitative first pass myocardial perfusion MRI with and without prospective slice tracking: comparison between breath-hold and free-breathing condition.

Physiologic motion of the heart is one of the major problems of myocardial blood flow quantification using first pass perfusion-MRI method. To overcome these problems, a perfusion pulse sequence with prospective slice tracking was developed. Cardiac motion was monitored by a navigator directly positioned at heart's basis to overcome no additional underlying model calculations connecting diaphra...

متن کامل

A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla.

BACKGROUND The breathhold contrast-enhanced three-dimensional magnetic resonance angiography (MRA) using T1-weighted gradient-echo imaging sequence is the standard technique for MRA of the thorax. However, this technique is not desirable for certain patients with respiratory insufficiency, serious renal impairment, or allergy to contrast agents. The objective of this study was to optimize and e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 49 6  شماره 

صفحات  -

تاریخ انتشار 2014