Neutral carrier-based "Ca(2+)-selective" microelectrodes for the measurement of tetraphenylphosphonium.

نویسندگان

  • V K Mootha
  • S French
  • R S Balaban
چکیده

Ca(2+)-selective microelectrodes with Simon's neutral carrier ETH 1001 are commercially available and have been widely used for the measurement of both extra- and intracellular calcium. The electrodes demonstrate high selectivity against other cations such as magnesium, sodium, and potassium. We report, however, that the ETH 1001-based microelectrode is a superior tetraphenylphosphonium (TPP+)-sensitive electrode. The electrode exhibits a Nernstian response for [Ca2+] > 10(-5) M but for [TTP+] > 10(-7) M. Using two different methods, we found that log kTTPCa (selectivity coefficient for TPP+ with respect to Ca2+) is in the range of -3.0 to -5.3. We argue that the ETH 1001 microelectrode can be used as a commercially available TPP+ electrode. We illustrate this application by making membrane potential recordings in respiring mitochondria. The results are identical to those obtained using conventional ion-exchange TPP+ electrodes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

Design and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids

Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...

متن کامل

Novel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix

In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...

متن کامل

(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies

A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...

متن کامل

Scanning Electrochemical Microscopy. 28. Bon-Selective Neutral CarriermBased Microelectrode Potent iometry

Electrodes for scanning ion-selective potentiometric microscopy (or potentiometric SECM) were developed and used to image local concentration profiles of NH4+, K+, and Zn2' ions. Neutral carrier-based micropipet ionselective electrodes with high spatial resolution (-2-3 pm) and fast response time (-300 ms) were fabricated and employed as potentiometric SECM tips, and highresolution ion-selectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical biochemistry

دوره 236 2  شماره 

صفحات  -

تاریخ انتشار 1996