Kinematic analysis of a posterior-stabilized knee prosthesis.

نویسندگان

  • Zhi-Xin Zhao
  • Liang Wen
  • Tie-Bing Qu
  • Li-Li Hou
  • Dong Xiang
  • Jia Bin
چکیده

BACKGROUND The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. METHODS Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. RESULTS Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. CONCLUSIONS There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair

BACKGROUND Total knee arthroplasty is effective to regain quality of life. Standing up from and sitting down on a chair and stair stepping motion are important in daily living. We previously reported in vivo kinematics of this implant during a stepping exercise. The purpose of this analysis was to assess in vivo knee motion during standing up from and sitting down on a chair and determine the m...

متن کامل

In vivo kinematics of a unique posterior-stabilized knee implant during a stepping exercise

BACKGROUND Stair-stepping motion is important in daily living, similar to gait. Knee prostheses need to have even more superior performance and stability in stair-stepping motion than in gait. The purpose of this analysis was to estimate in vivo knee motion in stair stepping and determine if this unique knee prosthesis function as designed. METHODS A total of 20 patients with Bi-Surface poste...

متن کامل

Standard versus high-flexion posterior stabilized total knee prostheses.

This meta-analysis compared clinical outcomes between standard and high-flexion posterior-stabilized total knee prostheses to evaluate which type of total knee prosthesis was superior. Randomized, controlled trials published until October 2013 comparing standard and high-flexion posterior-stabilized total knee prostheses were reviewed. Methodologic quality was assessed with the Physiotherapy Ev...

متن کامل

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...

متن کامل

ارزیابی کارایی گیت یک آمپوته همی پلویکتومی در حین راه رفتن با پروتز کانادین- گزارش موردی

Purpose: Hemipelvectomy amputation is a surgical procedure in which the lower limb and part of the pelvis are removed.  Although few studies are available on the performance of individuals with hip disarticulation while walking, there is no study on gait analysis of hemipelvectomy subjects. Therefore, this study aimed to evaluate the gait and stability of an individual with hemipelvectomy amput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chinese medical journal

دوره 128 2  شماره 

صفحات  -