Polymer-Free Biolimus A9-Coated Stents in the Treatment of De Novo Coronary Lesions: 4- and 12-Month Angiographic Follow-Up and Final 5-Year Clinical Outcomes of the Prospective, Multicenter BioFreedom FIM Clinical Trial.

نویسندگان

  • Ricardo A Costa
  • Alexandre Abizaid
  • Roxana Mehran
  • Joachim Schofer
  • Gerhard C Schuler
  • Karl E Hauptmann
  • Marco A Magalhães
  • Helen Parise
  • Eberhard Grube
چکیده

OBJECTIVES The purpose of this study was to evaluate the efficacy and long-term outcomes of a novel polymer/carrier-free drug-coated stent (DCS) in patients with de novo coronary lesions. BACKGROUND The BioFreedom (BFD) DCS incorporates a low-profile, stainless-steel platform, with a surface that has been modified to create a selectively microstructured abluminal surface that allows adhesion and further release of Biolimus A9 (Biosensors Europe SA, Morges, Switzerland). METHODS A total of 182 patients (183 lesions) were randomized into a 1:1:1 ratio for treatment with BFD "standard dose" (BFD) or BFD "low dose" (BFD-LD) versus first-generation paclitaxel-eluting stents (PES) at 4 sites in Germany. RESULTS Baseline and procedural characteristics were well matched. At 4-month angiographic follow-up (Cohort 1, n = 75), in-stent late lumen loss (LLL) was significantly lower with BFD and BFD-LD versus PES (0.08 and 0.12 mm vs. 0.37 mm, respectively; p < 0.0001 for BFD vs. PES, and p = 0.002 for BFD-LD vs. PES). At 12 months (Cohort 2, n = 107), in-stent LLL (primary endpoint) was 0.17 mm in BFD versus 0.35 mm in PES (p = 0.001 for noninferiority; p = 0.11 for superiority); however, the BFD-LD (0.22 mm) did not reach noninferiority (p = 0.21). At 5 years (175 of 182), there were no significant differences in major adverse cardiac events (23.8%, 26.4%, and 20.3%) and clinically indicated target lesion revascularization (10.8%, 13.4%, and 10.2%) for BFD, BFD-LD, and PES, respectively; also, there was no definite/probable stent thrombosis reported. CONCLUSIONS The BFD, but not the BFD-LD, demonstrated noninferiority versus PES in terms of in-stent LLL, a surrogate of neointimal hyperplasia, at 12-month follow-up. At 5 years, clinical event rates were similar, without occurrence of stent thrombosis in all groups. (BioFreedom FIM Clinical Trial; NCT01172119).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CRT 2017 late-breaking trials.

1. Impact of technique on early and late outcomes following coronary Bioresorbable scaffold implantation: Analysis from the ABSORB trials . . . . . 304 2. Two-year clinical outcomes of the ABSORB BVS compared EES: A propensity matched analysis of the BVS expand registry . . . . . . . . . . . . 305 3. Transcatheter aortic valve replacement using the Lotus valve with Depth Guard: First report fro...

متن کامل

Polymer-free biolimus a9-coated stent demonstrates more sustained intimal inhibition, improved healing, and reduced inflammation compared with a polymer-coated sirolimus-eluting cypher stent in a porcine model.

BACKGROUND Drug-eluting stents effectively reduce restenosis but may increase late thrombosis and delayed restenosis. Persistent polymer, the drug, or a combination of both could be responsible. Local delivery of Biolimus A9, a rapamycin derivative, from a polymer-free BioFreedom stent (Biosensors International) may prevent these complications. METHODS AND RESULTS We compared high-dose (HD) (...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Comparison of resolute zotarolimus-eluting stents and sirolimus-eluting stents in patients with de novo long coronary artery lesions: a randomized LONG-DES IV trial.

BACKGROUND Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo stent-based coronary interventions. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and sirolimus-eluting stents (SES) for patients with de novo long coronary lesions. METHODS AND RESULTS This randomized, multicenter, p...

متن کامل

A randomized comparison of the Endeavor zotarolimus-eluting stent versus the TAXUS paclitaxel-eluting stent in de novo native coronary lesions 12-month outcomes from the ENDEAVOR IV trial.

OBJECTIVES The ENDEAVOR IV (Randomized Comparison of Zotarolimus-Eluting and Paclitaxel-Eluting Stents in Patients with Coronary Artery Disease) trial evaluated the safety and efficacy of the zotarolimus-eluting stent (ZES) compared with the paclitaxel-eluting stent (PES). BACKGROUND First-generation drug-eluting stents have reduced angiographic and clinical restenosis, but long-term safety r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2016