Microsphere maps of regional blood flow and regional ventilation.

نویسندگان

  • H Thomas Robertson
  • Michael P Hlastala
چکیده

Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilation. With multiple radioactive or fluorescent microsphere labels available, this methodology can compare regional flow responses to different interventions without partial volume effects or registration errors that complicate interpretation of in vivo imaging measurements. Microsphere blood flow maps examined at different levels of spatial resolution have revealed that regional flow heterogeneity increases progressively down to an acinar level of scale. This pattern of scale-dependent heterogeneity is characteristic of a fractal distribution network, and it suggests that the anatomic configuration of the pulmonary vascular tree is the primary determinant of high-resolution regional flow heterogeneity. At approximately 2-cm(3) resolution, the large-scale gravitational gradients of blood flow per unit weight of alveolar tissue account for <5% of the overall flow heterogeneity. Furthermore, regional blood flow per gram of alveolar tissue remains relatively constant with different body positions, gravitational stresses, and exercise. Regional alveolar ventilation is accurately represented by the deposition of inhaled 1.0-microm fluorescent microsphere aerosols, at least down to the approximately 2-cm(3) level of scale. Analysis of these ventilation maps has revealed the same scale-dependent property of regional alveolar ventilation heterogeneity, with a strong correlation between ventilation and blood flow maintained at all levels of scale. The ventilation-perfusion (VA/Q) distributions obtained from microsphere flow maps of normal animals agree with simultaneously acquired multiple inert-gas elimination technique VA/Q distributions, but they underestimate gas-exchange impairment in diffuse lung injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Invited Review HIGHLIGHTED TOPIC Physiological Imaging of the Lung Microsphere maps of regional blood flow and regional ventilation

Robertson HT, Hlastala MP. Microsphere maps of regional blood flow and regional ventilation. J Appl Physiol 102: 1265–1272, 2007. First published December 7, 2006; doi:10.1152/japplphysiol.00756.2006.—Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilatio...

متن کامل

Chaotic Mixing Deep in the Lung Gravitational Deposition in a Rhythmically Expanding and Contracting Alveolus

[PDF] [Full Text] [Abstract] , July 23, 2002; 99 (15): 10173-10178. PNAS A. Tsuda, R. A. Rogers, P. E. Hydon and J. P. Butler Chaotic mixing deep in the lung [PDF] [Full Text] [Abstract] , August 1, 2003; 95 (2): 657-671. J Appl Physiol S. Haber, D. Yitzhak and A. Tsuda Gravitational deposition in a rhythmically expanding and contracting alveolus [PDF] [Full Text] [Abstract] , March 1, 20...

متن کامل

Spatial pattern of pulmonary blood flow distribution is stable over days.

Despite the heterogeneous distribution of regional pulmonary perfusion over space, local perfusion remains stable over short time periods (20-100 min). The purpose of this study was to determine whether the spatial distribution of pulmonary perfusion remains stable over longer time periods (1-5 days). Regional blood flow was measured each day for 5 days in five awake standing dogs. Fluorescent ...

متن کامل

EFFECTS OF HYPOXIC HYPOXIA AND CARBON MONOXIDE-INDUCED HYPOXIA ON THE CARDIOVASCULAR SYSTEM AND REGIONAL BLOOD FLOW OF THE ANESTHETIZED CAT

The purpose of this study was to investigate the potential responses of the cardiovascular system and regional blood flow to hypoxic hypoxia (BB) and to carbon monoxide (CO)-induced hypoxia (COH). Ten anesthetized cats were studied under two nonnoxic (control: CONT) and two hypoxic conditions. Four types of radioactive micro spheres were used to measure regional blood flow during CONT an...

متن کامل

Validation of CBF measurement with non-invasive microsphere method (NIMS) compared with autoradiography method (ARG).

The purpose of this study is to examine the correlation of measured regional cerebral blood flow (rCBF) by means of a new microsphere method (non-invasive microsphere method), to the autoradiography (ARG) method, which is an established quantification method for 123I-IMP brain SPECT. The non-invasive microsphere (NIMS) method and ARG method were simultaneously applied to 30 patients, and quanti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 102 3  شماره 

صفحات  -

تاریخ انتشار 2007