Expired hydrogen peroxide in breath condensate of cystic fibrosis patients.
نویسندگان
چکیده
Stimulated inflammatory cells release large amounts of hydrogen peroxide (H2O2). Breath condensate H2O2 has been shown to be elevated in stable asthmatic children, chronic obstructive pulmonary disease and intubated adult respiratory distress syndrome. In cystic fibrosis airways, where neutrophilic inflammation dominates, it is postulated that H2O2 in breath condensate would be elevated and may be used as a marker of airways inflammation. Expired breath condensate was collected from 16 clinically stable cystic fibrosis (CF) patients (mean age 25.3 yrs, mean forced expiratory volume in one second (FEV1) 50.2%) and 14 normal subjects (mean age 29.9 yrs). Total plasma leukocyte, neutrophil, monocyte and eosinophil counts and lung function were also measured on the day of collection. A method of breath condensate collection excluding the confounding factors of nasal air and saliva contamination was validated and used and H2O2 measured fluorometrically using an optimized assay. The median level of H2O2 concentration in breath condensate of CF patients was lower than that in normal subjects (0.064 versus 0.089 microM), but this did not reach statistical significance (p = 0.20, Mann-Whitney rank sum test). Within the CF group, there was no correlation between H2O2 concentration and lung function. Expired breath condensate H2O2 is not elevated in patients with cystic fibrosis, and is thus not a suitable marker of airways inflammation in these patients. Possible explanations include physical barriers to its detection caused by viscous airways secretions, reaction with other reactive species or increased antioxidant activity caused by trapping of positively charged antioxidants in negatively charged airways secretions.
منابع مشابه
Increased hydrogen peroxide and thiobarbituric acid-reactive products in expired breath condensate of asthmatic patients.
Symptoms of bronchial asthma are a manifestation of airway inflammation. Circulatory leucocytes (predominantly eosinophils, mast cells and neutrophils), release inflammatory mediators, including reactive oxygen species, i.e. superoxide anion which is dismutated to hydrogen peroxide (H2O2). Neutrophils from asthmatics generate greater amounts of these species than those of healthy subjects. Some...
متن کاملOxidant activity in expired breath of patients with adult respiratory distress syndrome.
Hydrogen peroxide levels were measured in the breath condensate of 43 patients receiving mechanical ventilation. In 16 patients the mean breath condensate peroxide level was 1.68 +/- 0.35 mumol/l on the day they met diagnostic criteria for adult respiratory distress syndrome (ARDS). The peak breath condensate peroxide level in the 27 patients in whom ARDS did not develop was significantly lower...
متن کاملHydrogen peroxide and nitric oxide in exhaled air of children with cystic fibrosis during antibiotic treatment.
Cystic fibrosis (CF) patients characteristically have severe chronic airway inflammation associated with bacterial infection. A noninvasive marker of airway inflammation could be a useful guide to treatment of CF lung disease. The aim of this study was to assess whether measurement of hydrogen peroxide (H2O2) and nitric oxide (NO) in exhaled air can serve to monitor the effect of treatment with...
متن کاملHydrogen peroxide in expired air condensate correlates positively with early steps of peripheral neutrophil activation in asthmatic patients.
We have found an increased H2O2 level in expired air of asthmatic patients. Neutrophils from these subjects generated higher amounts of superoxide radicals after challenge with phorbol esters than those from healthy subjects which may result from an increased activity of NADPH-oxidase. The enhanced Ca2+ mobilisation in neutrophils from asthmatics could be responsible for increased production an...
متن کاملAssessment of exhaled gases in ventilated preterm infants.
Hydrogen peroxide (H2O2) production in exhaled air was measured in ventilated preterm newborns at 5, 24 and 48 hours after delivery, using originally designed method of exhaled breath condensate (EBC) collection. H2O2 production in expired gas was 812+/-34 pmol/20 min during the first measurement and then declined to 389+/-21 at 24 hours and 259+/-26 pmol/20 min at 48 hours.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 13 1 شماره
صفحات -
تاریخ انتشار 1999