Gas-chromatographic analysis for cocaine in human plasma, with use of a nitrogen detector.
نویسندگان
چکیده
We describe a procedure for measuring the concentration of cocaine in plasma by gas chromatography, with use of a nitrogen detector. The procedure was tested on patients receiving intranasal cocaine for topical anesthesia. The propyl ester of benzoylecgonine is used as an internal standard. The lower limit of sensitivity of the procedure is 5--10 mug of cocaine per liter of plasma. The coefficients of variation are 5.3% and 3.0% for concentrations of 50 and 100 mug/liter, respectively.
منابع مشابه
Gas-chromatographic analysis for therapeutic concentration of imipramine and disipramine in plasma, with use of a nitrogen detector.
We describe a method for the simultaneous gas-chromatographic analysis of imipramine and desipramine (the active N-desmethyl metabolite) at therapeutic concentrations in human plasma, with use of a nitrogen detector. Imipramine is measured as the unchanged base and desipramine as its N-tribluoroacetyl derivative. Promazine is the internal standard. The lower limit of sensitivity is 5 mug/liter ...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملSimple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma
Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...
متن کاملDetermination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection
Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 13 شماره
صفحات -
تاریخ انتشار 1975