Carotid MR angiography using pulsed continuous arterial spin labeling
نویسندگان
چکیده
Introduction Carotid artery disease is a major cause of cerebral ischemia and infarction. It is routinely assessed using contrast-enhanced magnetic resonance angiography (MRA). Several methods for nonenhanced MRA exist, which may be particularly advantageous in patients with impaired renal function due to the risk of nephrogenic systemic fibrosis. Pulsed arterial spin-labeled (ASL) MRA has been investigated for carotid MRA, however, the signal to noise ratio (SNR) with the method is problematic when short repetition times are used to minimize scan time or when long labeling times are used to maximize visible vessel length. In contrast to pulsed ASL (PASL), we hypothesized that pulsed continuous ASL (PCASL) would provide improved SNR at short repetition times and/or long labeling durations.
منابع مشابه
Time-resolved noncontrast enhanced 4-D dynamic magnetic resonance angiography using multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR).
PURPOSE The goal of this study was to introduce a new noncontrast enhanced 4D dynamic MR angiography (dMRA) technique termed multibolus TrueFISP-based spin tagging with alternating radiofrequency (TrueSTAR). METHODS Multibolus TrueFISP-based spin tagging with alternating radiofrequency was developed by taking advantage of the phenomenon that the steady-state signal of TrueFISP is minimally di...
متن کاملQuantitative assessment of mixed cerebral vascular territory supply with vessel encoded arterial spin labeling MRI.
BACKGROUND AND PURPOSE Recent advances in arterial spin labeling MRI have permitted noninvasive evaluation of vascular territories. In the present study, we quantitatively assess mixing of internal carotid and basilar artery blood through cerebrovascular anastomoses using vessel-encoded arterial spin labeling and a new postprocessing method. METHODS Vessel-encoded arterial spin labeling was u...
متن کاملSingle Coil Amplitude Modulated Continuous Arterial Spin Labeling Perfusion MR at 3.0 Tesla
J. Wang, Y. Zhang, R. L. Wolf, A. C. Roc, D. C. Alsop, J. A. Detre Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States, Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States, Department of Radiology, Harvard Medical School, Boston, MA, United States Introduction Recently technical developments demonstrated a greater than 2-fold SNR...
متن کاملAssessment of collateral supply by two-coil continuous arterial spin labeling after coil occlusion of the internal carotid artery.
A patient undergoing coil occlusion of a left internal carotid artery aneurysm was investigated by continuous arterial spin labeling MR imaging to evaluate perfusion territory mapping. Labeling was restricted to the left- or right-sided carotid artery by use of a separate neck coil. Before embolization, perfusion contrast was largely restricted to the labeled hemisphere. After embolization, per...
متن کاملContinuous arterial spin labeling using a local magnetic field gradient coil.
Continuous arterial spin labeling (ASL) using a locally induced magnetic field gradient for adiabatic inversion of spins in the common carotid artery of human volunteers is demonstrated. The experimental setup consisted of a helmet resonator for imaging, a circular RF surface coil for labeling, and gradient loops to produce a magnetic field gradient. A spin-echo (SE) echo-planar imaging (EPI) s...
متن کامل