The present paper investigates how a storage unit, coupled with a wind farm could influence the economic operation of the power system. For this reason two optimization algorithms are implemented, where the storage capacity is assigned certain costs and is able to vary in size. The objective of the first optimization is to identify the optimal power infeed as well as the necessary battery capacity in order to maximize the profits of the wind farm. The objective of the second optimization is to identify the necessary battery capacity, which in relationship with the wind power infeed will minimize the total costs of the system. The wind farm is assumed to provide “cheap” energy to the network and has no knowledge of the effects its power infeed has on the Locational Marginal Prices (LMPs) it receives. It has been found that for small wind farms, which cannot influence the LMPs with their infeed, the maximum profit policy coincided with the power infeed policy for the minimization of the costs. On the contrary, the wind farm could not identify the optimal policy which would maximize its profits, when its size is big enough to influence the LMPs. Incentives are identified so that the wind farm can receive a price signal which will be of benefit for both the wind farm and the system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Operation of CHP Combined Heat Generation Systems Using the Crow Search Optimization Algorithm

Energy efficiency of power plants is less than 60% However, the efficiency of the CHP units can be up to 90 %.CHP units in addition to high efficiency, They reduce environmental pollutants by 13 to 18 percent. The purpose of this thesis is to use the simultaneous power and power generation plants to reach the optimal economic destination for Genco And to maximize economic profit And to minimize...

متن کامل

Distributed Generation Effects on Unbalanced Distribution Network Losses Considering Cost and Security Indices

Due to the increasing interest on renewable sources in recent years, the studies on integration of distributed generation to the power grid have rapidly increased. In order to minimize line losses of power systems, it is crucially important to define the size and location of local generation to be placed. Minimizing the losses in the system would bring two types of saving, in real life, one is ...

متن کامل

Distributed Generation Effects on Unbalanced Distribution Network Losses Considering Cost and Security Indices

Due to the increasing interest on renewable sources in recent years, the studies on integration of distributed generation to the power grid have rapidly increased. In order to minimize line losses of power systems, it is crucially important to define the size and location of local generation to be placed. Minimizing the losses in the system would bring two types of saving, in real life, one is ...

متن کامل

Optimal Scheduling of Coordinated Wind-Pumped Storage-Thermal System Considering Environmental Emission Based on GA Based Heuristic Optimization Algorithm

The integration of renewable wind and pumped storage with thermal power generation allows for dispatch of wind energy by generation companies (GENCOs) interested in participation in energy and ancillary services markets. However, to realize the maximum economic profit, optimal coordination and accounting for reduction in cost for environmental emission is necessary. The goal of this study is to...

متن کامل

Implementation of Optimal Load Balancing Strategy for Hybrid Energy Management System in DC/AC Microgrid with PV and Battery Storage

The proposed paper presents the DC/AC microgrid modeling using the Energy storage units and photovoltaic (PV) panels. The modal consists of a two stage power conversion. The power is supplied to the both DC and AC loads by this PV solar panels. The suitable way to explore the PV generation model is by using manufacturer datasheet. A bidirectional converter is connected to the battery storage sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011