Label-Free Determination of the Number of Biomolecules Attached to Cells by Measurement of the Cell's Electrophoretic Mobility in a Microchannel
نویسندگان
چکیده
We developed a label-free method for a determination of the number of biomolecules attached to individual cells by measuring the electrophoretic mobility of the cells in a microchannel. The surface of a biological cell, which is dispersed in aqueous solution, is normally electrically charged and the charge quantity at the cell's surface is slightly changed once antibody molecules are attached to the cell, based on which we detect the attachment of antibody molecules to the surface of individual red blood cells by electrophoretic mobility measurement. We also analyzed the number of antibody molecules attached to the cell's surface using a flow cytometer. We found that there is a clear correlation between the number of antibody molecules attached to the individual cells and the electrophoretic mobility of the cells. The present technique may well be utilized not only in the field of cell biology but also in the medical and pharmaceutical industries.
منابع مشابه
A simulation study on the performance of various label-free electronic biosensors
The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate fiel...
متن کاملA simulation study on the performance of various label-free electronic biosensors
The efficient detection of charged biomolecules by biosensor with appropriate semiconducting nanomaterials and with optimum device geometry has caught tremendous research interest in the present decade. Here, the performance of various label-free electronic biosensors to detect bio-molecules is investigated by simulation technique. Silicon nanowire sensor, nanosphere sensor and double gate fiel...
متن کاملApplication of the Phenomenological Model to Electrophoretic Mobility in Mixed Solvent Electrolyte Systems in Capillary Zone Electrophoresis
The phenomenological model of Khossravi and Connors (1992) has been adopted to calculate the electrophoretic mobility of drugs at different concentrations of solvents in a binary mixture. The accuracy and predictability of the model have been evaluated employing 14 experimental data sets by using average percentage mean deviation (APMD). The obtained APMD for correlative and predictive studies ...
متن کاملApplication of the Phenomenological Model to Electrophoretic Mobility in Mixed Solvent Electrolyte Systems in Capillary Zone Electrophoresis
The phenomenological model of Khossravi and Connors (1992) has been adopted to calculate the electrophoretic mobility of drugs at different concentrations of solvents in a binary mixture. The accuracy and predictability of the model have been evaluated employing 14 experimental data sets by using average percentage mean deviation (APMD). The obtained APMD for correlative and predictive studies ...
متن کاملA Semi-empirical Model to Predict the Attached Axisymmetric Shock Shape
In this work, a simple semi-empirical model is proposed, based on Response Surface Model, RSM, to determine the shape of an attached oblique shock wave emanating from a pointed axisymmetric nose at zero angle of attack. Extensive supersonic visualization images have been compiled from various nose shapes at different Mach numbers, along with some others performed by the author for the present p...
متن کامل