Verification of the Performance of a Vertical Ground Heat Exchanger Applied to a Test House in Melbourne, Australia
نویسندگان
چکیده
The ground heat exchanger is traditionally used as a heat source or sink for the heat pump that raises the temperature of water to about 50 ◦C to heat houses. However, in winter, the heating thermostat (temperature at which heating begins) in the Australian Nationwide House Energy Rating Scheme (NatHERS) is only 20 ◦C during daytime and 15 ◦C at night. In South-East Melbourne, the temperature at the bottom of a 50-m-deep borehole has been recorded with an EmersonTM recorder at 17 ◦C. Melbourne has an annual average temperature of 15 ◦C, so the ground temperature increases by 2 ◦C per 50-m depth. A linear projection gives 23 ◦C at 200-m of depth, and as the average undisturbed temperature of the ground for a 400-m-deep vertical ground heat exchanger (VGHE). This study, by simulation and experimentation, aims to verify that the circulation of water in the VGHE’s U-tube to low-temperature radiators (LTRs) could heat a house to thermal comfort. A literature review is included in the introduction. A simulation, using a model of a 60-m2 experimental house, shows that the daytime circulation of water in this VGHE/LTR-on-opposite-walls system during the 8-month cold half of the year, heats the indoors to NatHERS settings. Simulation for the cold half shows that this VGHE-LTR system could cool the indoors. Instead, a fan creating a cooling sensation of up to 4 ◦C is used so that the VGHE is available for the regeneration of heat extracted from the ground during the cold portion. Simulations for this hot portion show that a 3.4-m2 flat plate solar collector can collect more than twice the heat extracted from the ground in the cold portion. Thus, it can thus replenish the ground heat extracted for houses double the size of this 60-m2 experimental house. Therefore, ground heat is sustainable for family-size homes. Since no heat pump is used, the cost of VGHE-LTR systems could be comparable to systems using the ground source heat pump. Water circulation pumps and fans require low power that can be supplied by photovoltaic thermal (PVT). The EnergyPlusTM v8.7 object modeling the PVT requires user-defined efficiencies, so a PVT will be tested in the experimental house.
منابع مشابه
Cost and performance data for residential buildings fitted with GSHP systems in Melbourne Australia
The data reported in this article presents actual installation costs and performance data for a selection of residential Ground Source Heat Pump (GSHP) systems in Melbourne, Australia. The installation cost data includes five main cost components: ground loop installation, head pipe installation, heat pump, mechanical room installation, and fittings. The performance data presented here includes...
متن کاملEffect of baffle oientation on shell tube heat exchanger performance
In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...
متن کاملInvestigating Tubes Material Selection on Thermal Stress in Shell Side Inlet Zone of a Vertical Shell and Tube Heat Exchanger
In this study, the effect of the tube material on the thermal stress generated in a vertical shell and tube heat exchanger is investigated. Shell and tube heat exchangers are the most common heat exchangers used in industries. One of the most common failures in these exchangers in the industry is the tube failure at the junction of the tube to tubesheet. When the shell side and the tube side fl...
متن کاملMinimization of Entransy Dissipations of a Finned Shell and Tube Heat Exchanger
Improving heat transfer and performance in a radial, finned, shell and tube heat exchanger is studied in this study. According to the second law of thermodynamics, the most irreversibilities of convective heat transfer processes are due to fluid friction and heat transfer via finite temperature difference. Entransy dissipations are due to the irreversibilities of convective heat transfer. There...
متن کاملOptimization of Double Pipe Fin-pin Heat Exchanger Using Entropy Generation Minimization
In the current work optimization of double pipe fin-pin heat exchanger has been studied. The effective parameters those are controlling the heat exchanger performance are divided in two categories; geometrical and operating conditions. Using the Brent’s optimization algorithm and handling the thermodynamically design concept, one can minimize entropy generation in different length of heat excha...
متن کامل