The effect of spectral smearing on the identification of pure F0 intonation contours in vocoder simulations of cochlear implants.
نویسندگان
چکیده
OBJECTIVES Performance of cochlear implant (CI) users on linguistic intonation recognition is poorer than that of normal-hearing listeners, due to the limited spectral detail provided by the implant. A higher spectral resolution is provided by narrow rather than by broad filter slopes. The corresponding effect of the filter slope on the identification of linguistic intonation conveyed by pitch movements alone was tested using vocoder simulations. METHODS Re-synthesized intonation variants of naturally produced phrases were processed by a 15-channel noise vocoder using a narrow (40 dB/octave) and a broad (20 dB/octave) filter slope. There were three different intonation patterns (rise/fall/rise-fall), differentiated purely by pitch and each associated to a different meaning. In both slope conditions as well as a condition with unprocessed stimuli, 24 normally hearing Dutch adults listened to a phrase, indicating which of two meanings was associated to it (i.e. a counterbalanced selection of two of the three contours). RESULTS As expected, performance for the unprocessed stimuli was better than for the vocoded stimuli. No overall difference between the filter conditions was found. DISCUSSION AND CONCLUSIONS These results are taken to indicate that neither the narrow (20 dB/octave) nor the shallow (40 dB/octave) slope provide enough spectral detail to identify pure F(0) intonation contours. For users of a certain class of CIs, results could imply that their intonation perception would not benefit from steeper slopes. For them, perception of pitch movements in language requires more extreme filter slopes, more electrodes, and/or additional (phonetic/contextual) cues.
منابع مشابه
Speech, Hearing and Language: work in progress Volume 13 Spectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling (CIS) cochlear implants
Four-band and single-band noise-excited vocoders were used in acoustic simulations to investigate spectral and temporal cues to melodic pitch in the output of a cochlear implant speech processor. Noise carriers were modulated by amplitude envelopes extracted by half-wave rectification and low-pass filtering at 32 or 400 Hz. The fourband, but not the single-band processors, may preserve spectral...
متن کاملEffects of envelope-vocoder processing on F0 discrimination and concurrent-vowel identification.
OBJECTIVE The aim of this study was to examine the effects of envelope-vocoder sound processing on listeners' ability to discriminate changes in fundamental frequency (F0) in anechoic and reverberant conditions and on their ability to identify concurrent vowels based on differences in F0. DESIGN In the first experiment, F0 difference limens (F0DLs) were measured as a function of number of env...
متن کاملSpectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling cochlear implants.
Four-band and single-band noise-excited vocoders were used in acoustic simulations to investigate spectral and temporal cues to melodic pitch in the output of a cochlear implant speech processor. Noise carriers were modulated by amplitude envelopes extracted by half-wave rectification and low-pass filtering at 32 or 400 Hz. The four-band, but not the single-band processors, may preserve spectra...
متن کاملEnhancement of temporal periodicity cues in cochlear implants: effects on prosodic perception and vowel identification.
Standard continuous interleaved sampling processing, and a modified processing strategy designed to enhance temporal cues to voice pitch, were compared on tests of intonation perception, and vowel perception, both in implant users and in acoustic simulations. In standard processing, 400 Hz low-pass envelopes modulated either pulse trains (implant users) or noise carriers (simulations). In the m...
متن کاملSpectral Subband Centroids for Tone Vocoder Simulations of Cochlear Implants
Cochlear Implants (CIs) have long been used to partially restore hearing in profoundly deaf individuals through direct electrical stimulation of the auditory nerve. Changes in pitch due to electrode selection have been shown to conform to the tonotopic organisation of the cochlea; i.e., each electrode corresponds to a localised band of the human hearing spectrum. Studies have shown that it may ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cochlear implants international
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2015