Stimulus duration, neural adaptation, and sweep visual evoked potential acuity estimates.

نویسندگان

  • W H Ridder
  • D McCulloch
  • A M Herbert
چکیده

PURPOSE Results in several studies have suggested that the visual evoked potential (VEP) amplitude can vary with stimulus duration. The purpose of this study was to determine whether acuity estimates obtained by extrapolation of the sweep VEP are altered by this adaptation effect. METHODS Sweep VEP data were obtained from 16 healthy observers under binocular viewing conditions. Data were acquired with a commercially available VEP unit using standard electrode recording techniques. Three sweeps (high spatial frequencies, medium spatial frequencies, and low spatial frequencies) were run. The subjects' visual acuity at the monitor distance was 6/6 for the high spatial frequency sweep. For the medium and low spatial frequency sweeps, the subjects were dioptrically blurred to 6/15 (medium spatial frequencies) or 6/30 (low spatial frequencies) at the monitor distance. Each sweep consisted of six spatial frequencies (contrast 80%; temporal frequency (TF) = 7.5 Hz; screen luminance = 100 candela [cd]/m2). For each spatial frequency, the stimulus duration was 8 seconds, partitioned into 1-second bins. A minimum of eight sweeps were obtained per subject. An acuity estimate was obtained for each second's data by fitting a line to the high spatial frequencies (excluding noise) and extrapolating this line to the x-axis. With this technique, estimates could not be obtained for 29 of 384 possible acuities. RESULTS The sweep VEP acuities for the 16 subjects did not change significantly over the 8 seconds of data collection for the high, medium, or low spatial frequency sweep (repeated measures analysis of variance [ANOVA]: high, P = 0.25; medium, P = 0.50; low, P = 0.23). In any given subject, there was a 1- to 2-octave range in acuity estimates over the 8 seconds of stimulus presentation (high, 1.23+/-0.417 octaves; medium, 1.41+/-0.593 octaves; low, 1.52+/-0.475 octaves; mean +/- SD). CONCLUSIONS These results suggest that there is not a significant change in sweep VEP acuity estimates over an 8-second stimulus presentation. Thus, neural adaptation does not significantly affect the clinical use of the sweep VEP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sweep visual evoked potential testing as a predictor of recognition acuity in albinism.

OBJECTIVE To determine if sweep visual evoked potential (VEP) acuity is predictive of recognition acuity in children with albinism. METHODS A retrospective review was performed in children with albinism who underwent sweep VEP testing from 1992 to 2003. All patients had a complete ophthalmologic examination with either binocular or monocular sweep VEP testing and at least 5 years of follow-up...

متن کامل

Visual acuity in unilateral cataract.

BACKGROUND Patching the fellow eye in infancy is a well recognised therapy to encourage visual development in the lensectomised eye in cases of unilateral congenital cataract. The possibility of iatrogenic deficits of the fellow eye was investigated by comparing the vision of these patients with untreated unilateral patients and binocularly normal controls. METHODS Sweep visual evoked potenti...

متن کامل

Acute laser lesion effects on acuity sweep VEPs.

Q-switched neodymium-YAG (infrared) laser lesions at energies up to and including retinal hemorrhages were placed under visual control in the parafovea and the fovea of anesthetized monkeys. Visual-evoked potential (VEP) data were obtained by parallel analog (vector voltmeter) techniques from scalp electrodes in response to high luminance counterphasing sine wave gratings. The gratings were swe...

متن کامل

Rapid assessment of visual function: an electronic sweep technique for the pattern visual evoked potential.

We have developed an electronic spatial frequency sweep technique for electrophysiological assessment of visual acuity and pattern vision. The technique allows an accurate and reliable measurement of VEPs to a full range of spatial frequencies in just 10 sec. Because the measurements are so rapid, the technique suggests several new improvements in the assessment of visual function. Sweeping spa...

متن کامل

Dysfunction in the fellow eyes of strabismic and anisometropic amblyopic children assessed by visually evoked potentials Alterações dos potenciais visuais evocados nos olhos contralaterais de crianças com ambliopia estrabísmica e anisometrópica

Approved by the following research ethics committee: Federal University of São Paulo (approval no 0503/08). ABSTRACT Purpose: To evaluate visual acuity and transient pattern reversal (PR) visual evoked potentials (VEPs) in the fellow eyes of children with strabismic and/or anisometropic amblyopia. Methods: Children diagnosed with strabismic and/or anisometropic amblyopia were recruited for elec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 39 13  شماره 

صفحات  -

تاریخ انتشار 1998