Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.
نویسندگان
چکیده
Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the blood cultures and 22% of the broth cultures were contaminated (P = 0.06). Staphylococcus epidermidis-contaminated cultures represented 31 and 10% of the blood and broth cultures, respectively (P = 0.06). Contamination of plates processed on a bench top, in front of horizontal laminar flow, and in a biological safety cabinet with vertical laminar flow were compared. Processing plates in a biological safety cabinet resulted in a significant reduction in the number of contaminated plates (P less than 0.05). The contamination rate for 7,874 Isolator blood cultures processed in the biological safety cabinet was significantly decreased to 6.7% on-streak (9.3% on- plus off-streak). Contamination of Isolator-processed blood cultures originated from the laboratory and the patient. The former can be reduced by inoculating plates in a vertical laminar flow biological safety cabinet and by maintaining adequate quality control of media. The latter may be unavoidable.
منابع مشابه
A comparison of lysis centrifugation, pour plate, and conventional blood culture methods in the diagnosis of septicaemic melioidosis.
AIMS To determine whether quantitative blood culture methods could improve the diagnosis of septicaemic melioidosis. METHODS A comparison of conventional broth based blood cultures, a pour plate method, and a commercial lysis centrifugation (Isolator 10) blood culture system was conducted in 71 Thai patients with severe melioidosis. The time to identification of B pseudomallei was recorded fo...
متن کاملLack of utility of the lysis-centrifugation blood culture method for detection of fungemia in immunocompromised cancer patients.
We retrospectively compared the utility of a fungal isolation device (Isolator) versus conventional techniques for recovering fungal organisms from blood cultures obtained from neutropenic cancer patients. Positive cultures were deemed true pathogens, possible pathogens, or contaminants according to laboratory and clinical criteria. Fifty-three patients had 66 positive blood cultures for fungi,...
متن کاملComparison of blood culture methods for recovery of Legionella pneumophila from the blood of guinea pigs with experimental infection.
Blood was cultured from guinea pigs with experimental Legionella pneumophila serogroup 1 pneumonia, using four different methods. A 0.03-ml amount was spread onto each of several plates of buffered charcoal-yeast extract supplemented with alpha-ketoglutarate (BCYE) (direct plate); 1.5 ml each was inoculated into a BCYE agar-yeast extract broth bottle (biphasic), a pediatric Isolator tube (E. I....
متن کاملEvaluation of a lysis direct plating method for pediatric blood cultures.
The Isolator 1.5 Microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) is a commercially available blood culture system for use in pediatrics. The methodology is based on blood lysis followed by direct plating of the sample on culture media to detect bacteria and fungi. Comparative recovery rates of pathogens from blood collected in this and a conventional broth system were si...
متن کاملClinical comparison of lysis-centrifugation and radiometric resin systems for blood culture.
The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) and the BACTEC 16B-17D radiometric resin system (Johnston Laboratories, Inc., Towson, Md.) both remove antimicrobial agents from the blood for culture. We compared these two systems for recovery of aerobic bacteria, facultatively anaerobic bacteria, and yeasts. A total of 5,000 blo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 19 2 شماره
صفحات -
تاریخ انتشار 1984