High-performance liquid-chromatographic simultaneous determination of commonly used tricyclic antidepressants.

نویسندگان

  • H F Proelss
  • H J Lohmann
  • D G Miles
چکیده

We report a method for simultaneous measurement of five commonly used tricyclic antidepressant drugs (doxepin, desipramine, nortriptyline, imipramine, and amitriptyline) in serum by paired-ion high-performance liquid chromatography, with use of a reversed-phase column and ultraviolet detection at 254 nm. The drugs are extracted from 2 ml of serum at pH 14 into hexane/isoamyl alcohol (99/1 by vol) and re-extracted into 200 microliter of 0.1 mol/liter HCI. An aliquot of the aqueous acid phase is chromatographed with use of a methanol/acetonitrile/water (41/15/44) solvent system, containing 5 mmol of pentanesulfonic acid per liter of phosphate buffer (0.1 mol/liter, pH 6.5), at a flow rate of 1,5 ml/min. Analytical recoveries of the drugs from serum increase with increasing concentration, from 62% at 25 microgram/liter to 93% at 300 microgram/liter. Linear response is observed for drug concentrations up to 1500 microgram/liter and the detection limit is 2-3 microgram/liter. Within-run precision ranges from 1.4 to 2.9% and day-to-day precision from 1.7 to 7%, depending on the specific drug. The entire procedure can be completed within 45 min and is well adapted to the routine clinical laboratory. Of 48 common basic and several neutral drugs tested for possible interferences, only three benzodiazepines, three phenothiazines, and three antihistamines interfere with the assay of doxepin, desipramine, and nortriptyline, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reversed-phase liquid chromatography and gas chromatography/mass fragmentography compared for determination of tricyclic antidepressant drugs.

We compare measurement of the tricyclic antidepressants desipramine, imipramine, nortryptaline, and amitryptaline by reversed-phase "high-performance" liquid chromatography and by gas chromatography/mass fragmentography. The liquid-chromatographic procedure does not require ion-pairing reagents, and involves detection at 215 nm. The within-day and between-day CVs for this method were less than ...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 11  شماره 

صفحات  -

تاریخ انتشار 1978