Immature Granulocyte Count on the New Sysmex Xn9000: Performance and Diagnosis of Sepsis in the Intensive Care Unit
نویسندگان
چکیده
Introduction. The amount of immature leukocytes reflects marrow response to bacterial infection, and this may be quantified as the band or immature granulocyte (IG) count. The aim of this study was to analyze the IG count performance of the Sysmex XN-9000 hematology analyzer in intensive care unit (ICU) patients. Methods. 480 peripheral blood samples from adult patients admitted to the ICU (301 control, 119 sepsis and 60 septic shock) were analyzed with Sysmex XN-9000. Serum C reactive protein (CRP) was measured on Siemens ADVIA 2400. IG count in peripheral blood was determined either by XN-9000 or optical microscopy (OM). Agreement between the two methods was assessed with Pearson’s correlation, Passing-Bablok regression and Bland Altman bias. Diagnostic accuracy was estimated through ROC curves analysis. Sysmex XN-9000 imprecision and within-run precision were also evaluated. Results. Pearson’s correlation (r) relative to IG count, as absolute and percentage values, was 0.89 (p <0.0001) and 0.74 (p <0.0001), respectively, with a Bias of 0.22 and 1.69 respectively. The Area Under the curve (AUC) for the IG count for diagnosing sepsis was greater on XN-9000 than OM and equal to the serum CRP. The diagnostic accuracy of IG counts improves when taking into account the conventional criteria for diagnosing sepsis. Conclusion. IG count appears suitable and reliable when performed using XN-9000. Even if a modest overestimation was found, the diagnostic accuracy showed by IG analysis on XN-9000 may represent a valid alternative to OM count for diagnosing sepsis in ICU patients.
منابع مشابه
Immature granulocyte measurement using the Sysmex XE-2100. Relationship to infection and sepsis.
We determined the usefulness of immature granulocyte measurement as a predictor of infection or positive blood culture and compared the results with total WBC count and absolute neutrophil count (ANC). Blood samples from 102 infected and 69 noninfected patients were analyzed using the Sysmex XE-2100 automated blood cell counter (Sysmex, Kobe, Japan). The percentage of immature granulocytes was ...
متن کاملAssociation of the immature platelet fraction with sepsis diagnosis and severity
Management of Sepsis would greatly benefit from the incorporation of simple and informative new biomarkers in clinical practice. Ideally, a sepsis biomarker should segregate infected from non-infected patients, provide information about prognosis and organ-specific damage, and be accessible to most healthcare services. The immature platelet fraction (IPF) and immature reticulocyte fraction (IRF...
متن کاملDelta neutrophil index as an early marker of disease severity in critically ill patients with sepsis
BACKGROUND The immature granulocyte count has been reported to be a marker of infection and sepsis. The difference in leukocyte subfractions (delta neutrophil index, DNI) in ADVIA 2120 reflects the fraction of circulating immature granulocytes in the blood. This study evaluated the clinical utility of DNI as a severity and prediction marker in critically ill patients with sepsis. METHODS One ...
متن کاملPerformance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.
Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...
متن کاملEvaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte
Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...