Transmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.

نویسندگان

  • Kyunghyun Sung
  • Bruce L Daniel
  • Brian A Hargreaves
چکیده

PURPOSE To quantify B1+ variation across the breasts and to evaluate the accuracy of precontrast T1 estimation with and without B1+ variation in breast MRI patients at 3 Tesla (T). MATERIALS AND METHODS B1+ and variable flip angle (VFA) T1 mapping were included in our dynamic contrast-enhanced (DCE) breast imaging protocol to study a total of 25 patients on a 3.0T GE MR 750 system. We computed precontrast T1 relaxation in fat, which we assumed to be consistent across a cohort of breast imaging subjects, with and without compensation for B1+ variation. The mean and standard deviation of B1+ and T1 values were calculated for statistical data analysis. RESULTS Our measurements showed a consistent B1+ field difference between the left and right breasts. The left breast has an average 15.4% higher flip angle than the prescribed flip angle, and the right breast has an average 17.6% lower flip angle than the prescribed flip angle. This average 33% flip angle difference, which can be vendor and model specific, creates a 52% T1 estimation bias in fat between breasts using the VFA T1 mapping technique. The T1 variation is reduced to 7% by including B1+ correction. CONCLUSION We have shown that severe B1+ variation over the breasts can cause a substantial error in T1 estimation between the breasts, in VFA T1 maps at 3T, but that compensating for these variations can considerably improve accuracy of T1 measurements, which can directly benefit quantitative breast DCE-MRI at 3T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of B1 Inhomogeneity on Enhancement Ratio Measurements Using Dce-mri of the Breast at 3t

Introduction Dynamic contrast-enhanced (DCE)-MRI has been proven to be very useful in the diagnosis and prognosis of breast cancer. In the recent years, 3T MR scanners have become more common in routine diagnostic imaging. The main advantage of high field imaging is the improved signal to noise ratio. However, the major drawback is that there is an increased inhomogeneity in radiofrequency tran...

متن کامل

Parallel Excitation: Making SENSE of High-Field Body MRI

MR imaging at high B0 field strength presents significant diagnostic opportunities derived from enhancements in SNR, spectral resolution and image contrast. However there are technical challenges that substantially hamper the practice of high-field MRI, including a major one that is related to the exploitation of the radio frequency EM field (B1 field and concomitant E field). As field strength...

متن کامل

Simutaneous measurement of pharmacokinetic model parameters and T1/B1 using Active Contrast Encoding MRI

Introduction: T1-weighted dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been widely used to probe tumor microenvironment using kinetic model parameters, such as transfer constant K, extra cellular space volume fraction ve, and vascular space volume fraction vp. Accurate estimation of these kinetic parameters requires B1-corrected T1 values [1]. However, it is not trivial to...

متن کامل

FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) by

FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) Zhenghui Zhang, PhD University of Pittsburgh, 2006 This thesis concentrates on the reduction of field (both main field B0 and RF field B1) inhomogeneity in MRI, especially at high B0 field. B0 and B1 field inhomogeneity are major hindrances in high B0 field MRI applications. B1 inhomogeneity will lead to spatially v...

متن کامل

Feasibility of a fast method for B1-inhomogeneity correction for FSPGR sequences.

The Fast Spoiled Gradient Echo (FSPGR) sequence is often used in MRI to create T1-weighted images. The signal intensity generated by this sequence depends on the applied flip angle. Knowing the correct flip angle is essential for the determination of T1-maps by means of an FSPGR based Variable Flip Angle (VFA) approach. Also, quantitatively determining the concentration of contrast agent in cas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2013