Multi-detector row CT systems and image-reconstruction techniques.

نویسندگان

  • Thomas G Flohr
  • Stefan Schaller
  • Karl Stierstorfer
  • Herbert Bruder
  • Bernd M Ohnesorge
  • U Joseph Schoepf
چکیده

The introduction in 1998 of multi-detector row computed tomography (CT) by the major CT vendors was a milestone with regard to increased scan speed, improved z-axis spatial resolution, and better utilization of the available x-ray power. In this review, the general technical principles of multi-detector row CT are reviewed as they apply to the established four- and eight-section systems, the most recent 16-section scanners, and future generations of multi-detector row CT systems. Clinical examples are used to demonstrate both the potential and the limitations of the different scanner types. When necessary, standard single-section CT is referred to as a common basis and starting point for further developments. Another focus is the increasingly important topic of patient radiation exposure, successful dose management, and strategies for dose reduction. Finally, the evolutionary steps from traditional single-section spiral image-reconstruction algorithms to the most recent approaches toward multisection spiral reconstruction are traced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...

متن کامل

Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography--influence of image reconstruction interval on graft visibility.

PURPOSE To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-...

متن کامل

Spatial variation of resolution and noise in multi-detector row spiral CT.

RATIONALE AND OBJECTIVES The authors performed this study to evaluate an approach for measuring the variations of three-dimensional spatial resolution and image noise throughout a field of view imaged with multi-detector row spiral computed tomographic (CT) scanners. MATERIALS AND METHODS The authors designed a phantom (diameter, 320 mm) that contained 37 metallic spheres (diameter, approxima...

متن کامل

Cone-Beam Reconstruction Using Filtered Backprojection

The art of medical computed tomography is constantly evolving and the last years have seen new ground breaking systems with multi-row detectors. These tomographs are able to increase both scanning speed and image quality compared to the single-row systems more commonly found in hospitals today. This thesis deals with three-dimensional image reconstruction algorithms to be used in future generat...

متن کامل

A Simple Algorithm for Increased Helical Pitch in Cone-Beam CT

A goal of cone-beam CT is to decrease the scan time needed to image a volume of the patient. Four things are required to meet this goal: (1) a detector with multiple rows of sensors, (2) higher bandwidth data acquisition system and image processor to handle the increased data rates and need for fast reconstruction, (3) high helical pitch, (4) a practical reconstruction algorithm that lends itse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 235 3  شماره 

صفحات  -

تاریخ انتشار 2005