Electrogenerated chemiluminescence detection of mercury(II) ions based on DNA probe labeled with ruthenium complex.

نویسنده

  • Yaping Li
چکیده

A novel mercury(II) ion (Hg(2+)) biosensor with electrogenerated chemiluminescence (ECL) detection using tris(2,2'-bipyridyl) ruthenium derivatives (ruthenium complex) as labeling was developed in the prescent work. One thymine (T)-rich single-strand DNA (ssDNA) labeled with a ruthenium complex was taken as an ECL probe. When the other T-rich capture ssDNA was self-assembled onto the surface of a gold electrode with a thiol group, and then hybridized with the ECL probe to form double-strand DNA (dsDNA) structures in the presence of Hg(2+), a strong ECL response was electrochemically generated. The ECL intensity was linearly related to the concentration of Hg(2+) in the range from 1.0 × 10(-6) to 1 × 10(-9) M with a detection limit of 3.0 × 10(-10) M. The relative standard deviation was 4.1% at 1.0 × 10(-7) M Hg(2+) (n = 5). This work demonstrates that the combination of the strongly binding T-rich DNA to Hg(2+) with the highly sensitive ECL technique to design an ECL Hg(2+) biosensor is a great promising approach for the determination of metal ions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrogenerated chemiluminescence. 68. Detection of sodium ion with a ruthenium(II) complex with crown ether moiety at the 3,3'-positions on the 2,2'-bipyridine ligand.

We show here how a Ru(bpy)2(CE-bpy) complex can be used for the ECL detection of sodium ion in both aqueous and nonaqueous media. Recognition of Na+ by the crown ether moiety in CE-bpy results in a significant increase in the ECL emission intensity of the complex.

متن کامل

Fabrication of CdTe@SiO2 nanoprobes for sensitive electrogenerated chemiluminescence detection of DNA damage.

Detection of DNA damage is significant for the evaluation of genotoxicity of new chemicals in the early stages of its development. An electrogenerated chemiluminescence (ECL) biosensor was fabricated to detect specific sequences of DNA by using CdTe@SiO2 as nanoprobes for signal amplification. This DNA biosensor was constructed by self-assembly of an aminated capture DNA on the glass carbon ele...

متن کامل

Electrochemical investigations of the interaction of metal chelates with DNA. 3. Electrogenerated chemiluminescent investigation of the interaction of tris(1,10-phenanthroline)ruthenium(II) with DNA.

The electrogenerated chemiluminescence (ECL) that results from the oxidation of tris(1,10-phenanthroline)ruthenium(II), at a gold electrode in the presence of oxalate, was used to investigate the interaction of the Ru(II) chelate with calf thymus DNA. The decrease in ECL emission from the excited state, Ru(phen)3(2+*), in the presence of DNA, is ascribed to binding to binding of the chelate to ...

متن کامل

Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol–gel-derived titania–Nafion composite films

A highly sensitive and stable tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)3) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol–gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania–Nafion composite solution. Th...

متن کامل

Electrogenerated chemiluminescence Part 54. Electrogenerated chemiluminescence of ruthenium( II) 4,4’-diphenyl-2,2’-bipyridine and ruthenium( II) 4,7-diphenyl-l,lO-phenanthroline systems in aqueous and acetonitrile solutions

The electrogenerated chemiluminescence (ECL) of Ru(dp-bpy):+ (dp-bpy = 4,4’-diphenyl-2,2’bipyridine) and Ru(dp-phen):+ (dp-phen = 4,7-diphenyl-l,lO-phenanthroline) in acetonitrile and aqueous solutions was studied. The diphenyl-substituted compounds produced a more intense emission than the nonsubstituted Ru(bpy):+ Ru(dp-phen):+ m acetonitrile. The ECL efficiencies, dECL, of Ru(dp-bpy):+ and we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 27 2  شماره 

صفحات  -