Evidence of multiple pathways capable of emitting peroxyoxalate chemiluminescence using a charge coupled device spectrometer.
نویسندگان
چکیده
Peroxyoxalate chemiluminescence (PO-CL) spectra obtained simultaneously and continuously using a CCD spectrometer provide evidence of the complexity of PO-CL reactions.
منابع مشابه
Development of an immune microanalysis system by use of peroxyoxalate chemiluminescence detection.
We developed an immune microanalysis system incorporating chemiluminescence detection, where the peroxyoxalate chemiluminescence (CL) detection using bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate (TDPO)-hydrogen peroxide (H2O2)-fluorescein isothiocianate (FITC) reaction was newly adopted. The analysis system performed the following three processes on a microchip: immune reaction fo...
متن کاملChemiluminescence Properties of Peroxyoxalate System in Organic Solvents
Peroxyoxalate system includes an oxalate ester, peroxide and a fluorescer, The energy resulted from the reaction of oxalate ester and peroxide is transferred to fluorescer and cause it to fluorsc. The effect of reactants chemical structure, their concentration, solvent media (polarity and viscosity) and the temperature, on the intensity of the illuminated light with respect to time have bee...
متن کاملA Study of Chemiluminescence from Reaction of Bis(2,4,6-trichlorophenyl)oxalate–H2O2 in the Presence of a Novel Blue Fluorescer, Furandicarboxylate Derivative
The chemiluminescence (CL) arising from the reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) with H2O2 in the presence of a novel blue fluorescer, furandicarboxylate derivative, has been studied. The relationship between the CL intensity and concentrations of peroxyoxalate, sodium salicylate, H2O2 and furandicarboxylate derivative as fluorescer has been investigated. Kinetic parameters for ...
متن کاملAutomatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.
A fully automated and highly sensitive method with a semi-microcolumn liquid chromatography system for the determination of rat plasma catecholamines (CAs) was developed. Automated on-line extraction of CAs in diluted plasma using a precolumn packed with strong acidic cation exchange resin was coupled with separation of CAs on a semi-microcolumn (250 x 1.5 mm id). fluorogenic derivatization wit...
متن کاملInfluences of Device Architectures on Characteristics of Organic Light-Emitting Devices Incorporating Ambipolar Blue-Emitting Ter(9,9-diarylfluorenes)
In this article, we report the studies of various device architectures of organic lightemitting devices (OLEDs) incorporating highly efficient blue-emitting and ambipolar carriertransport ter(9,9-diarylfluorene)s, and their influences on device characteristics. The device structures investigated include single-layer devices and multilayer heterostructure devices employing the terfluorene as one...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemical communications
دوره 47 19 شماره
صفحات -
تاریخ انتشار 2011