Intrafraction displacement of prone versus supine prostate positioning monitored by real‐time electromagnetic tracking

نویسندگان

  • Wayne M. Butler
  • Gregory S. Merrick
  • Joshua L. Reed
  • Brian C. Murray
  • Brian S. Kurko
چکیده

Implanted radiofrequency transponders were used for real-time monitoring of the intrafraction prostate displacement between patients in the prone position and the same patients in the supine position. Thirteen patients had three transponders implanted transperineally and were treated prone with a custom-fitted thermoplastic immobilization device. After collecting data from the last fraction, patients were realigned in the supine position and the displacements of the transponders were monitored for 5-7 minutes. Fourier transforms were applied to the data from each patient to determine periodicity and its amplitude. To remove auto correlation from the stream of displacement data, the distribution of short-term and long-term velocity components were calculated from Poincaré plots of paired sequential vector displacements. The mean absolute displacement was significantly greater prone than supine in the superior-inferior (SI) plane (1.2 ± 0.6 mm vs. 0.6 ± 0.4 mm, p= 0.015), but not for the lateral or anterior-posterior (AP) planes. Displacements were least in the lateral direction. Fourier analyses showed the amplitude of respiratory oscillations was much greater for the SI and AP planes in the prone versus the supine position. Analysis of Poincaré plots confirmed greater short-term variance in the prone position, but no difference in the long-term variance. The centroid of the implanted transponders was offset from the treatment isocenter by > 5 mm for 1.9% of the time versus 0.8% of the time for supine. These results confirmed significantly greater net intrafraction prostate displacement of patients in the prone position than in the supine position, but most of the difference was due to respiration-induced motion that was most pronounced in the SI and AP directions. Because the respiratory motion remained within the action threshold and also within our 5 mm treatment planning margins, there is no compelling reason to choose one treatment position over the other.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی‌مقایسه‌ای‌میزان‌اشباع‌اکسیژن‌خون‌شریانی‌نوزادان‌نارس‌دچار سندرم‌دیسترس‌تنفسی‌در دو وضعیت‌دمر و طاقباز

  Background : Neonatal period is one of the most important periods in human's life. Low birth weight and immaturity is often the cause of death. (weight less them 1000grm and pregnancy less than 30 weeks). One of the main cause of death in this period is respiratory distress syndrome.   Objective : To determine the effect of prone and supine positioning oxygenation in preterm infants with resp...

متن کامل

Prostate Intrafraction Translation Margins for Real-Time Monitoring and Correction Strategies

The purpose of this work is to determine appropriate radiation therapy beam margins to account for intrafraction prostate translations for use with real-time electromagnetic position monitoring and correction strategies. Motion was measured continuously in 35 patients over 1157 fractions at 5 institutions. This data was studied using van Herk's formula of (αΣ + γσ') for situations ranging from ...

متن کامل

Investigation of oxygenation in premature infants under mechanical ventilation in supine position compare to side lying

Abstract Introduction: Changing position is an important aspect within nursing care. Prone positioning amongst premature infants could improve their oxygenation compared to supine position. Side lying position leads to developed support between premature infants, however there is few studies about effects of this position on premature infants 'oxygenation. Objective: This study was conduc...

متن کامل

Real‐time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...

متن کامل

Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT

BACKGROUND Image-guidance systems allow accurate interfractional repositioning of IMRT treatments, however, these may require up to 15 minutes. Therefore intrafraction motion might have an impact on treatment precision. 3D geometric data regarding intrafraction prostate motion are rare; we therefore assessed its magnitude with pre- and post-treatment fiducial-based imaging with cone-beam-CT (CB...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013