Biological contamination of insulin pens in a hospital setting.
نویسندگان
چکیده
PURPOSE Biological contamination of insulin pens in a hospital setting was studied. METHODS This prospective study, conducted at two hospitals within a multihospital system, examined 125 insulin pens that had been returned to the inpatient pharmacies after patient discharge and were refrigerated for up to 48 hours before laboratory testing. Insulin was removed from the 125 pens and examined microscopically for the presence of nucleated cells and red blood cells (RBCs). Positive samples were examined by a pathologist to determine the cell types present. An immunochromatographic assay was used to determine the presence of free hemoglobin in the insulin. The 10 control samples were negative on microscopic examination. RESULTS Out of 125 insulin pens, 7 (5.6%) tested positive for cells or hemoglobin. Microscopic examination revealed six positive samples containing a total of nine cells, including macrophages, squamous cells, and an RBC. The sample containing the RBC was not the same sample that tested positive for hemoglobin. Based on findings of intact cells and hemoglobin in insulin pens after administration, the potential exists for transmission of infectious agents from patient to patient if a single pen cartridge is used to administer insulin to multiple patients, even if a new needle is used for each individual. CONCLUSION Examination of 125 insulin pens used in hospitals revealed hemoglobin in 1 pen and at least one cell in another 6 pens. The nine detected cells consisted of four squamous epithelial cells, four macrophages, and one RBC.
منابع مشابه
A Prospective Study for Introducing Insulin Pens and Safety Needles in a Hospital Setting. The SANITHY Study.
BACKGROUND to assess costs and safety of insulin pen devices and safety needles as compared to vial/syringes in hospitalized patients requiring insulin therapy in a General Hospital in Northern Italy. MATERIALS AND METHODS in a prospective 9-month study, consecutive patients admitted to three Hospital Units received insulin therapy through either a traditional disposable syringe method, or pe...
متن کاملEconomic Impact of Converting from Pen and 10-mL Vial to 3-mL Vial for Insulin Delivery in a Hospital Setting.
PURPOSE To compare the impact on acquisition cost and purchased volume of rapid- and short-acting insulins following conversion from 3-mL disposable pens and 10-mL vials to 3-mL vials for individual patient supply (IPS) in a hospital setting. METHODS On February 1, 2010, St. Joseph's Hospital and Medical Center of Dignity Health in Phoenix, Arizona, converted from pens to 3-mL vials for IPS s...
متن کاملEconomic impact of converting from 10-mL insulin vials to 3-mL vials and pens in a hospital setting.
PURPOSE The economic impact associated with the conversion from 10-mL vials of insulin to 3-mL vials and pens at a community hospital was assessed. METHODS Pharmacy purchasing and administrative data from Providence St. Vincent Hospital in Portland, Oregon, were used in this analysis. The hospital converted floor-stock 10-mL vials of insulin in October 2010 to individual patient supply (IPS) ...
متن کاملDose accuracy of the ClikSTAR, NovoPen 4, and Luxura insulin pens: results of laboratory and field studies.
BACKGROUND A high dosing accuracy is needed to maintain normal glycemia in patients with diabetes. This study investigated the dose accuracy of the commonly used reusable insulin pens ClikSTAR®, NovoPen® 4, and Luxura®. METHODS Pens were tested in a laboratory setting by one trained technician who delivered four doses of 30 U from each of 15 pens per pen model (a total of 60 doses from each p...
متن کاملComparison of clinically relevant technical attributes of five insulin injection pens.
BACKGROUND Insulin injection pens are the predominant devices for insulin delivery in Europe and Japan because of their ease of use and convenience. This study compared clinically relevant technical attributes of durable insulin pens that are important to people with diabetes, specifically functions relating to cartridge-fitting, dose-setting, and dose-delivery on NovoPen® 4, ClikStar®, HumaPen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists
دوره 70 14 شماره
صفحات -
تاریخ انتشار 2013