Volumetric navigators for real-time motion correction in diffusion tensor imaging.
نویسندگان
چکیده
Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the contrast is independent of the b-value, to perform prospective motion correction in diffusion weighted images, without having to reacquire volumes during which motion occurred, unless motion exceeded some preset thresholds. Water phantom and human brain data were acquired using the standard and navigated diffusion sequences, and the mean and whole brain histogram of the fractional anisotropy and mean diffusivity were analyzed. Our results show that adding the navigator does not influence the diffusion sequence. With head motion, the whole brain histogram-fractional anisotropy shows a shift toward lower anisotropy with a significant decrease in both the mean fractional anisotropy and the fractional anisotropy histogram peak location (P<0.01), whereas the whole brain histogram-mean diffusivity shows a shift toward higher diffusivity with a significant increase in the mean diffusivity (P<0.01), even after retrospective motion correction. These changes in the mean and the shape of the histograms are recovered substantially in the prospective motion corrected data acquired using the navigated sequence.
منابع مشابه
Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging
Thesis: Implementation of Anatomical Navigators for Real Time Motion Correction in Diffusion Tensor Imaging Author‟s Name: Alkathafi A. Alhamud Date: 10-02-2012 Diffusion Tensor Imaging (DTI) is used to detect microstructural changes in the human brain. Although echo planar imaging (EPI) has been implemented in diffusion pulse sequences to minimize the effect of subject motion, motion artifacts...
متن کاملDiffusion tensor MRI of the human heart In Vivo with a navigator based free breathing approach
Background Diffusion tensor MRI (DTI) provides a non-invasive approach for the depiction of the myocardial fibre architecture [1-5]. In vivo DTI remains extremely challenging due to the need for motion correction. Several techniques have been used to compensate for respiratory motion: multiple breath-holds (>36 per patient), synchronised breathing and retrospective navigators based on image cro...
متن کاملReal-time optical motion correction for diffusion tensor imaging.
Head motion is a fundamental problem in brain MRI. The problem is further compounded in diffusion tensor imaging because of long acquisition times, and the sensitivity of the tensor computation to even small misregistration. To combat motion artifacts in diffusion tensor imaging, a novel real-time prospective motion correction method was introduced using an in-bore monovision system. The system...
متن کاملHybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors
INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...
متن کاملProspective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs)
Prospective head motion correction in 3D FLASH using EPI-based volumetric navigators (vNavs) M. Dylan Tisdall, Himanshu Bhat, Keith Heberlein, and André J. W. van der Kouwe A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States, Radiology, Harvard Medical School, Boston, Massachusetts, United States, Siemens Medical Solutions USA ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 68 4 شماره
صفحات -