Voltammetric method based on an ion-pairing reaction for the determination of trace amount of iodide at carbon-paste electrodes.

نویسندگان

  • Qiong He
  • Junjie Fei
  • Shengshui Hu
چکیده

Carbon-paste electrodes (CPEs) were studied to elucidate the cathodic stripping voltammetric determination of iodine. At an accumulation potential of 1.0 V (vs. SCE), iodide was preconcentrated on CPEs via an ion-pairing reaction, followed by oxidation to iodine. Then a linear scan voltammogram was recorded after 10 s of quiescent time by a cathodic potential scan from 0.7 V to 0.1 V at a scan rate of 100 mV s(-1). A cathodic peak current was obtained at about 0.38 V. Various experiment parameters such as the acidity, chloride concentration, accumulation potential, accumulation time, concentration of cetyltrimethylammonium bromide (CTAB) and scan rate, were optimized to analyze the iodide by employing linear-scan stripping voltammetry. Under the optimal conditions, calibration curves were obtained over a wide concentration range of the iodide ion from 8 x 10(-9) mol L(-1) to 5 x 10(-6) mol L(-1) with a detection limit of 2 x 10(-9) mol L(-1) at an accumulation time of 3 min. The effect of interfering species was evaluated and the procedure was applied to an iodide analysis in table salt, with good results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)

In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...

متن کامل

A Simple and an Effective Catalyst for Determination of Cefixime in Real Samples Using of Modified Carbon Paste Electrode with Cobalt Impregnated Zeolite

Carbon paste electrode modified with cobalt impregnated zeolite was prepared by mixing of cobalt_zeolite (Co_Z) and graphite powder with different percent. The electrochemical oxidation of cefixime at such electrodes was investigated using the cyclic voltammetric and amperometric techniques. It is not electrochemically active towards cefixime oxidation in 0.1 M phosphate buffer solution (pH=7) ...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Study and optimization of the necessary conditions for the sensitive determination of the lead ion by a modified carbon paste electrode in environmental water samples

Rapid and facile preparation of the cheap modified electrode materials is an important parameter in development of the efficient electrochemical sensor for industrial scale production and mass-market usage. In the present work, the carbon paste electrode modified with multi-walled carbon nanotubes (MWCNTs) was prepared for sensitive determination of lead (Pb) ion in the presence of bismuth (Bi)...

متن کامل

Study and optimization of the necessary conditions for the sensitive determination of the lead ion by a modified carbon paste electrode in environmental water samples

Rapid and facile preparation of the cheap modified electrode materials is an important parameter in development of the efficient electrochemical sensor for industrial scale production and mass-market usage. In the present work, the carbon paste electrode modified with multi-walled carbon nanotubes (MWCNTs) was prepared for sensitive determination of lead (Pb) ion in the presence of bismuth (Bi)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 2003