Peak expiratory flow and the resistance of the mini-wright peak flow meter.

نویسندگان

  • O F Pedersen
  • T R Rasmussen
  • O Omland
  • T Sigsgaard
  • P H Quanjer
  • M R Miller
چکیده

The purpose of this study was to examine whether the resistance of the peak flow meter influences its recordings. One hundred and twelve subjects, (healthy nonsmokers and smokers and subjects with lung diseases) performed three or more peak expiratory flow (PEF) manoeuvres through a Fleisch pneumotachograph with and without a mini-Wright peak flow meter added in random order as a resistance in series. The results were as follows. In comparison with a pneumotachograph alone, peak flow measured with an added mini-Wright meter had a smaller within-test variation, defined as the difference between the highest and second highest values of PEF in a series of blows. The mean (SE) variation was 14 (1.3) L.min-1 and 19 (1.5) L.min-1 with and without meter added, respectively. In comparison with the pneumotachograph alone, the addition of the mini-Wright meter caused PEF to be underread, especially at high flows. The difference (PEF with meter minus PEF without meter) = -0.064 (average PEF) -8 L.min-1; R2 = 0.13. The mean difference was -7.8 (1.1) %, and increased numerically for a given PEF, when maximal expiratory flow when 75% forced vital capacity remains to be exhaled (MEF75%FVC) decreased. The reproducibility criteria for repeated measurements of peak flow are more appropriately set at 30 L.min-1 than the commonly used 20 L.min-1, because a within-test variation of less than 30 L.min-1 was achieved in 76% of the subjects without PEF meter inserted and in 88% with meter inserted, with no difference between healthy untrained subjects and patients. The resistance of the peak expiratory flow meter causes less variation in recordings but reduces peak expiratory flow, especially at high values and when the peak is large as compared with the rest of the maximal expiratory flow-volume curve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Normal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran

Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...

متن کامل

Peak expiratory flow at altitude.

The mini Wright peak flow meter is a useful, portable instrument for field studies but being sensitive to air density will under-read at altitude. True peak expiratory flow will increase at altitude, however, because of the decreased air density, given that dynamic resistance is unchanged. The effect of simulated altitude on peak expiratory flow (PEF) was determined in six subjects with both th...

متن کامل

Measuring peak expiratory flow in general practice: comparison of mini Wright peak flow meter and turbine spirometer.

OBJECTIVE To compare measurements of the peak expiratory flow rate taken by the mini Wright peak flow meter and the turbine spirometer. DESIGN Pragmatic study with randomised order of use of recording instruments. Phase 1 compared a peak expiratory flow type expiration recorded by the mini Wright peak flow meter with an expiration to forced vital capacity recorded by the turbine spirometer. P...

متن کامل

Gas compression in lungs decreases peak expiratory flow depending on resistance of peak flowmeter.

It has recently been shown (O. F. Pedersen T. R. Rasmussen, O. Omland, T. Sigsgaard, P. H. Quanjer. and M. R. Miller. Eur. Respir. J. 9: 828-833, 1996) that the added resistance of a mini-Wright peak flowmeter decreases peak expiratory flow (PEF) by approximately 8% compared with PEF measured by a pneumotachograph. To explore the reason for this, 10 healthy men (mean age 43 yr, range 33-58 yr) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 1996