Feasibility study for linac-based intensity modulated total marrow irradiation.
نویسندگان
چکیده
Total body irradiation (TBI) is used as a preconditioning regimen prior to bone marrow transplant for treatment of hematologic malignancies. During TBI, large volumes of normal tissue are irradiated, and this can lead to toxicities, most significantly in the lungs. Intensity modulated total marrow irradiation (IMTMI) may be able to reduce these toxicities by directly targeting the bone marrow while minimizing the dose to critical structures. The goal of this study was to assess the feasibility of IMTMI by following the planning and delivery process for a Rando phantom. A three isocenter technique was used to provide a full body plan for treatment on a linear accelerator. Thermoluminescent detectors (TLDs) were placed at 22 positions throughout the phantom to compare the delivered doses to the planned doses. Individual intensity modulated radiation therapy verification plans were delivered to a solid water phantom for the three isocenters, and doses measured from an ion chamber and film were compared to the planned doses. The treatment plan indicated that target coverage was achieved with this IMTMI technique, and that the doses to critical structures were reduced by 29%-65% compared to conventional TBI. TLD readings demonstrated accurate dose delivery, with an average difference of 3.5% from the calculated dose. Ion chamber readings for the verification plans were all within 3% of the expected dose, and film measurements showed accurate dose distributions. Results from this study suggest that IMTMI using the three isocenter technique can be accurately delivered and may result in substantial dose reductions to critical structures.
منابع مشابه
Targeted total marrow irradiation using three-dimensional image-guided tomographic intensity-modulated radiation therapy: an alternative to standard total body irradiation.
Total body irradiation (TBI) is an important part of bone marrow transplantation conditioning regimens. In TBI, dose escalation is difficult, because of associated normal organ toxicities. A method to deliver a more targeted dose of TBI preferentially to sites of greatest tumor burden is needed to reduce the dose to normal organs, reduce toxicities, and permit dose escalation. The purpose of th...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملReal-time tumor tracking during VMAT radiotherapy treatments based on 2D/3D registration using CBCT projections
Rotational radiotherapy treatments such as volumetric modulated arc therapy (VMAT) can have superior overall quality while having shorter delivery time with respect to conventional intensity modulated radiotherapy (IMRT). As with conventional treatments, intrafractional tumor motion is a major source of uncertainty in dose application. To ensure full tumor coverage the planning target volume (P...
متن کاملA set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation.
The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beam...
متن کاملUtility of Smart Arc CDR for intensity-modulated radiation therapy for prostate cancer
Volumetric-modulated arc therapy (VMAT) is a widespread intensity-modulated radiation therapy (IMRT) method, however, VMAT requires adaptation of the radiation treatment planning system (RTPS) and linear accelerator (linac); these upgrades are quite expensive. The Smart Arc of Pinnacle(3) (Philips), which is the software used in VMAT calculations, can select constant dose rate (CDR) mode. This ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 35 12 شماره
صفحات -
تاریخ انتشار 2008