Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device

نویسندگان

  • Patrycja Smolarek-Kasprzak
  • John M Nolan
  • Stephen Beatty
  • Jessica Dennison
  • Kwadwo Owusu Akuffo
  • Robert Kuchling
  • Jim Stack
  • Graham O'Regan
چکیده

Purpose. To compare measures of visual acuity (VA) and contrast sensitivity (CS) from the Thompson Xpert 2000 and MultiQuity (MiQ) devices. Methods. Corrected distance VA (CDVA) and CS were measured in the right eye of 73 subjects, on an established system (Thompson Xpert) and a novel system (MiQ 720). Regression was used to convert MiQ scores into the Thompson scale. Agreement between the converted MiQ and Thompson scores was investigated using standard agreement indices. Test-retest variability for both devices was also investigated, for a separate sample of 24 subjects. Results. For CDVA, agreement was strong between the MiQ and Thomson devices (accuracy = 0.993, precision = 0.889, CCC = 0.883). For CS, agreement was also strong (accuracy = 0.996, precision = 0.911, CCC = 0.907). Agreement was unaffected by demographic variables or by presence/absence of ocular pathology. Test-retest agreement indices for both devices were excellent: in the range 0.88-0.96 for CDVA and in the range 0.90-0.98 for CS. Conclusion. MiQ measurements exhibit strong agreement with corresponding Thomson measurements, and test-retest results are good for both devices. Agreement between the two devices is unaffected by age or ocular pathology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

P58: Visual Working Memory Performance Based on Saccades in Children with and without Specific Learning Disorder: An Eye-Tracking Study

Some of the previous studies show that children with SLD have deficits in visual processing and working memory. Hence, the aim of this research was to investigate problems of visual working memory based on behavioral neuroscience method, using an eye tracker device. The method of present study was ex-post facto study. The participants included couple of twelve children with SLD (mean age=10.92)...

متن کامل

Measuring The Quality Of Natural Lighting In A Building With Double Skin Façade (Dsf)

Lately, a double skin façade (DSF) has been increasingly popular as an aesthetic and shading device. A façade with a secondary skin is employed in buildings to let natural light flow into the building without glare and heat. The purpose of this study is to examine the performance of secondary skin in buildings and to investigate the level of natural lighting in buildings that meets visual comfo...

متن کامل

Comparative analysis of profit between three dissimilar repairable redundant systems using supporting external device for operation

The importance in promoting, sustaining industries, manufacturing systems and economy through reliability measurement has become an area of interest. The profit of a system may be enhanced using highly reliable structural design of the system or subsystem of higher reliability. On improving the reliability and availability of a system, the production and associated profit will also increase. Re...

متن کامل

Effects of Visual Biofeedback Therapy on Postural Balance of Stroke Patients

Purpose: Postural balance deficit is one of the common post-stroke disabilities. Providing visual biofeedback while balance activities are performed is a way to improve postural balance disorders following stroke. But among the research published, there is incoherency about the positive effects of visual biofeedback therapy. The purpose of this study was to investigate the effects of usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014