The Design of a TiNi Actuator in an Intramedullary Leg Lengthening Device

نویسندگان

  • A. Aalsma
  • E. Hekman
  • J. Stapert
  • H. Grootenboer
چکیده

Today's medical technology makes it possible to increase leg length for people with leg length discrepancies or excessively short limbs. With the Ilizarov method bones can be gradually elongated (max. Immlday) without implantation of bone grafts or multiple operations. Although the operative procedure is relatively simple, the negative side effects for the patient are considerable. An external fixator is mounted to the bone. The fixation is made by pins through the skin. Amongst the disadvantages of the external fixator are possible infection of the bone or soft tissue, minimal weight bearing and restricted possibility for wearing clothes. A design for a fully implantable extractor is proposed in order to eliminate these disadvantages for the patient. An actuator of TiNi alloy is chosen for inducing the displacement of 1 mmlday. The advantages of such an actuator are the biocompatibility and the small physical dimensions needed, where the maximum diameter of the medulla is only 13 mm. By using the Two Way Shape Memory Effect (TWSME) a very compact and simple actuator is designed. The most important factors in the design of the TWSME-actuator are the elongation, working force and transformation temperatures of the alloy. The TWSME-training method for the actuator used in our tests showed a sufficient generation of force and elongation. Differential Scanning Calometry measurements showed a shift in the transformation temperatures due to the training. This is a result of induced internal stresses by the training. Neither the amount of temperature shift nor the efficiency of the training were correlated to pre-training annealing temperatures (500°C-700°C).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Completely Intramedullary Leg Lengthening Device

The procedure and the external fixator for lengthening long bones was developed by G. A. Ilizarov in the late 1960's. This technique has, despite its proven abilities for leg lengthening and correction of angular deformities, some considerable disadvantages for the patients. Discomfort, infections and restricted weight bearing are some reasons for the development of a completely intramedullary ...

متن کامل

Intramedullary leg lengthening with a motorized nail

BACKGROUND AND PURPOSE In the last decade, intramedullary limb lengthening has become a viable alternative to traditional external systems. We retrospectively analyzed the use of an intramedullary motorized nail (Fitbone) in a consecutive series of 32 patients. PATIENTS AND METHODS During the period September 2006 to December 2008, 32 consecutive patients with a median age of 17 (IQR: 15-19) ...

متن کامل

Lengthening of the femur over an existing intramedullary nail.

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

TECHNICAL TRICK Lengthening of the Femur Over an Existing Intramedullary Nail

Leg length discrepancies can occur despite successful union of femur fractures after intramedullary nailing (IMN). Often, the leg length discrepancy can result in significant disability to the patient, altered gait biomechanics, pelvic obliquity, and pain. Therefore, a successful clinical result for such deformities after IMN involves addressing the leg length inequality. Femoral reconstruction...

متن کامل

Femoral lengthening with a motorized intramedullary nail

PURPOSE We assessed whether an intramedullary lengthening device would reduce the problems normally associated with the external fixation technique. We also wanted to determine whether it is a reliable construct for limb lengthening and deformity correction in the femur. PATIENTS AND METHODS We conducted a matched-pair comparison of 30 femoral lengthenings, 15 with a motorized intramedullary ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016