Diffusion-weighted single-shot line scan imaging of the human brain.
نویسندگان
چکیده
Single-shot line scan imaging (LSI) was adapted to diffusion-weighted (DW) MRI by replacing the initial 90 degrees radiofrequency pulse of the underlying high-speed stimulated echo sequence by a DW spin-echo preparation period. Implementation on a 2. 0 T whole-body MRI system yielded DW images of the human brain with b factors of 750 s mm(-2) and total imaging times of about 500 ms either for a single slice at 1.5 x 3.0 x 6 mm(3) resolution or simultaneously for up to seven slices at 3.75 x 3.75 x 8 mm(3) resolution. Isotropic DW images and maps of the trace of the diffusion tensor were calculated from four scans with different combinations of three orthogonal diffusion gradients. DW LSI combines high speed with robustness against image artifacts caused by motion (no phase ghosting) and tissue susceptibility differences (no signal losses, no geometric distortions). Because the latter is an important advantage over echo-planar imaging, DW LSI may find useful applications despite a limited signal-to-noise ratio. Magn Reson Med 42:772-778, 1999.
منابع مشابه
Diffusion tensor mapping of the human brain using single-shot line scan imaging.
A recently developed single-shot line scan imaging technique for diffusion measurements (Finsterbusch and Frahm, Magn Reson Med 1999;42:772-778) was extended to full diffusion tensor mapping of the human brain. Because the sequence acquires stimulated echoes from individual columns of magnetization ("lines"), the approach is affected neither by spatial aliasing when studying inner volumes nor b...
متن کاملComparison of Single-Shot Echo-Planar and Line Scan Protocols for Diffusion Tensor Imaging1
Rationale and Objectives. Both single-shot diffusion-weighted echo-planar imaging (EPI) and line scan diffusion imaging (LSDI) can be used to obtain magnetic resonance diffusion tensor data and to calculate directionally invariant diffusion anisotropy indices, ie, indirect measures of the organization and coherence of white matter fibers in the brain. To date, there has been no comparison of EP...
متن کاملSlab scan diffusion imaging.
For maximum robustness of a diffusion-weighted MR imaging sequence, it is desirable to use a single-shot imaging method. This article introduces a new single-shot imaging approach that combines the advantages of multiple spin-echoes with the technique of line scan diffusion imaging. A slab volume, which can be spatially encoded with fewer phase encodes than a regular field of view, is selected ...
متن کاملRapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging.
A subsecond magnetic resonance imaging (MRI) technique for isotropic diffusion mapping is described which, in contrast to echo-planar imaging (EPI), is insensitive to resonance offsets, i.e., tissue susceptibility differences, magnetic field inhomogeneities, and chemical shifts. It combines a diffusion-weighted (DW) spin-echo preparation period and a high-speed stimulated echo acquisition mode ...
متن کاملClinical feasibility of high-resolution single-shot diffusion tensor trace -weighted (ssTW) MRI
and negative (red) bipolar gradients results in cancelling contributions from off-diagonal diffusion tensor elements to the DW signal. Figure 2: A. Trace weighted MRIs acquired using our ssTW method in 15s across the entire brain. B. Brain tissue regions-of-interest (ROIs) C. Mean ADC map calculated from the ssTW scan. D. Mean ADC map calculated using DTI with 20 directions in 2 min. E. Directi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 42 4 شماره
صفحات -
تاریخ انتشار 1999