Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device.

نویسندگان

  • Matthew D Koff
  • Randy W Loftus
  • Corey C Burchman
  • Joseph D Schwartzman
  • Megan E Read
  • Elliot S Henry
  • Michael L Beach
چکیده

BACKGROUND Hand hygiene is a vital intervention to reduce health-care associated infections, but compliance remains low. The authors hypothesized that improvements in intraoperative hand hygiene compliance would reduce transmission of bacteria to surgical patients and reduce the incidence of postsurgical healthcare-associated infections. METHODS The authors performed a controlled before-and-after study over 2 consecutive months. One hundred fourteen operative cases were enrolled. Two predesignated sites on the anesthesia machine were selected, decontaminated, and cultured via aseptic technique. These sites and the peripheral intravenous stopcock were cultured again after completion of the surgery. The treatment phase used a novel personal hand-decontamination device capable of recording hand-decontamination events. RESULTS There were no significant differences in patient location, age, or case duration and procedure type between groups. Use of the Sprixx GJ device (Harbor Medical Inc., Santa Barbara, CA) increased hourly hand decontamination events by 27-fold as compared with baseline rates (P < 0.002; 95% confidence interval, 3.3-13.4). Use of the device was associated with a reduction in contamination in the anesthesia work area and peripheral intravenous tubing. Intravenous tubing contamination was identified in 32.8% of cases in the control group versus 7.5% in the treatment group (odds ratio, 0.17; 95% confidence interval, 0.06-0.51; P < 0.01). Healthcare-associated infections rates were reduced in the device group (3.8%) as compared with the control group (17.2%) (odds ratio, 0.19; 95% confidence interval, 0.00-0.81; P = 0.02). CONCLUSIONS Improved hand hygiene compliance through the use of a novel hand sanitation strategy reduces the risk of intraoperative bacterial transmission. The intervention was associated with a reduction in healthcare-associated infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran

There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...

متن کامل

Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran

There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...

متن کامل

Scrub the hub! Catheter needleless port decontamination.

T HE central venous catheter (CVC) is an essential tool in the care of critically ill and high-risk intraoperative patients. Catheterrelated bloodstream infection (CR-BSI) related to CVC insertion technique has been greatly reduced by the use of preventive protocols. However, late CR-BSI remains a significant threat to patient safety and healthcare cost containment. Appropriate CVC maintenance ...

متن کامل

Compodock, a new device for sterile docking.

BACKGROUND A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS Sterility of the connections was assessed by welding tubing with a heavy exterior contamination with Bacillus subtilis spores and also by welding in an environment contaminated with aer...

متن کامل

Developing a Novel Temperature Model in Gas Lifted Wells to Enhance the Gas Lift Design

In the continuous gas lift operation, compressed gas is injected into the lower section of tubing through annulus. The produced liquid flow rate is a function of gas injection rate and injection depth. All the equations to determine depth of injection assumes constant density for gas based on an average temperature of surface and bottomhole that decreases the accuracy of gas lift design. Also g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 110 5  شماره 

صفحات  -

تاریخ انتشار 2009