Using concha electrodes to measure cochlear microphonic waveforms and auditory brainstem responses.

نویسنده

  • Ming Zhang
چکیده

During electrocochleography, that is, ECochG or ECoG, a recording electrode can be placed in the ear canal lateral to the tympanic membrane. We designed a concha electrode to record both sinusoidal waveforms of cochlear microphonics (CMs) and auditory brainstem responses (ABRs). The amplitudes of CM waveforms and Wave I or compound action potentials (CAPs) recorded at the concha were greater than those recorded at the mastoid but slightly lower than those recorded at the ear canal. Wave V amplitudes recorded at the concha were greater than those recorded at the ear canal but lower than those recorded at the mastoid. There was not a significant difference between the amplitudes recorded at the concha and at the ear canal. For CM and Wave I or CAP, the latency recorded at the concha was longer than at the canal but shorter than at the mastoid; for Wave V, the reverse was true. However, these differences were not statistically significant and may be due to the distance to response generators. Aside from the advantages that the regular ECoG has over otoacoustic emission (OAE) testing, the concha electrode was also easier and safer to place and may be suitable for children, newborn screening, participants with canal conditions, and remote clinics which could have concerns with the availability and cost of a canal electrode. Using concha electrodes, we also experienced fewer postauricular artifacts than when using a mastoid electrode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mouse Auditory Brainstem Response Testing.

The auditory brainstem response (ABR) test provides information about the inner ear (cochlea) and the central pathways for hearing. The ABR reflects the electrical responses of both the cochlear ganglion neurons and the nuclei of the central auditory pathway to sound stimulation (Zhou et al., 2006; Burkard et al., 2007). The ABR contains 5 identifiable wave forms, labeled as I-V. Wave I represe...

متن کامل

Study of cochlear microphonic potentials in auditory neuropathy.

INTRODUCTION Auditory Neuropathy/Dyssynchrony is a disorder characterized by the presence of Otoacoustic Emissions and Cochlear Microphonic Potentials, an absence or severe alteration of Brainstem Evoked Auditory Potential, auditory thresholds incompatible with speech thresholds and altered acoustic reflexes. The study of the Cochlear Microphonic Potential appears to be the most important tool ...

متن کامل

Brief report: the cochlear microphonic as an indication of outer hair cell function.

The extra-cellular cochlear microphonic is believed to be generated predominantly by outer hair cells and therefore it would seem reasonable to assume that the presence of a cochlear microphonic excludes outer hair cell dysfunction. Indeed, a diagnosis of auditory neuropathy might be, and has been, made on the basis of a cochlear microphonic present with an abnormal auditory brainstem response....

متن کامل

Effects of Stimulus Intensity on Low-Frequency Toneburst Cochlear Microphonic Waveforms

This study investigates changes in amplitude and delays in low-frequency toneburst cochlear microphonic (CM) waveforms recorded at the ear canal in response to different stimulus intensities. Ten volunteers aged 20-30 were recruited. Low-frequency CM waveforms at 500 Hz in response to a 14-ms toneburst were recorded from an ear canal electrode using electrocochleography techniques. The data was...

متن کامل

Putative Auditory-Evoked Neurophonic Measurements Using a Novel Signal Processing Technique: A Pilot Case Study

With changes to cochlear implant candidacy and improvements in surgical technique, there is a need for accurate intraoperative assessment of low-frequency hearing thresholds during cochlear implantation. In electrocochleography, onset compound action potentials (CAPs) typically allow estimation of auditory threshold for frequencies above 1 kHz, but they are less accurate at lower frequencies. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Trends in amplification

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2010