Dose consumption for quality assurance and maintenance with a dedicated IORT accelerator
نویسنده
چکیده
Dedicated accelerators for intra-operative radiation therapy (IORT) are operated at high dose rates in order to achieve short treatment times within which the anaesthetisized patient must be remotely monitored (e.g. via video cameras and telemetric anesthesia instruments). Due to these high dose rates, large doses accumulate from the irradiations necessary for quality assurance (QA) and maintenance. In practice, the dose load for QA, maintenance and repairs will probably far exceed the patient dose. The total dose consumption for all of these actions must be considered in facility licensing, in radiation protection assessments, and in the shielding calculations. Dose consumption for QA and maintenance was assessed for the dedicated IORT facility at Heidelberg University for the operation period between June 1991 and December 2007 (15.5 years). Average doses per year of 5847 Gy for maintenance and repairs and 3686 Gy for QA were needed during this period. The causes and composition of these high doses are analyzed and discussed separately for irradiations that need to be performed in the operation room and which, with a mobile accelerator, may be performed in a separate QA vault.
منابع مشابه
Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran
Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملاعتبارسنجی سر شتابدهندۀ پرتودرمانی حین عمل جراحی LIAC با استفاده از روش مونتکارلو
With the development of science and technology in the medical field and need more than ever to accuracy and quality of treatment has been causer increase different radiotherapy methods. Almost the past two decade’s intraoperative radiation therapy (IORT) as one of the new techniques used to treat cancer patients. One of the problems with this method is obtaining accurate dosimetry, becaus...
متن کاملDosimetric pitfalls in the application of shielding disk in breast intraoperative electron radiation therapy
Introduction: Intraoperative electron radiotherapy (IOERT) is an IORT technique in which electron beams with different nominal energies are used for irradiation of microscopic residual of tumor bed after surgery. Application of a shielding disk, which is positioned under the target volume, for protecting the normal tissues such as pectoral muscle, lung, and heart is one of the a...
متن کاملQuality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device
Introduction: According to the American Society of Radiation Oncology, all patients receive radiation therapy during their illness, where radiation is delivered by the medical linear accelerator (Linac). The aim of this study was to evaluate the quality assurance (QA) of the Linac in analyzing the used dose profile in the treatment of cancer tumors. Materi...
متن کامل