Visual Improvement in High Myopic Amblyopic Adult Eyes following Phakic Anterior Chamber Intraocular Lens Implantation
نویسندگان
چکیده
PURPOSE To evaluate the efficacy and safety of angle-supported phakic anterior chamber intraocular lenses in amblyopic adult eyes with very high myopia. METHODS We evaluated 12 eyes in nine patients with very high myopic amblyopia who received angle-supported phakic intraocular lenses (Phakic 6H) and followed them for more than six months. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and complications were evaluated. A satisfaction score was rated by patients using a 5-point (1-5) numeric scale. RESULTS The mean age of patients was 37.3 +/- 9.4 years, ranging from 29 to 59 years old. The preoperative mean refraction (spherical equivalent, SE) was -20.10 +/- 5.41 diopters (D). The postoperative mean refraction (SE) was -1.75 +/- 0.76 D at six months. The postoperative BCVA improved an average 3.92 +/- 1.24 lines over preoperative values, and mean endothelial cell loss was 8.9% at six months. Development of cataracts, glaucoma, and pupil abnormalities were not demonstrated in any case during the study. The patients were all very satisfied, as the average satisfaction score was 4.3. CONCLUSIONS This study indicates that angle-supported phakic anterior chamber intraocular lens implantation may be an effective surgical alternative for the correction of amblyopic adult eyes with very high myopia. However, long-term evaluation is necessary to assess possible complications and long-term safety.
منابع مشابه
Intermittent myopic shift of 4.0 diopters after implantation of an Artisan iris-supported phakic intraocular lens.
A 45-year-old man with bilateral high myopia and myopic astigmatism had uneventful implantation of a -10.5 diopters (D) Artisan iris-fixated anterior chamber phakic intraocular lens (PIOL) (Ophtec) in both eyes. In the first days after surgery, uncorrected visual acuity (UCVA) was 20/16 in the right eye and 20/16 in the left; the position of the PIOL was stable. Ten days after surgery, the left...
متن کاملof ultra - high myopia in phakic eyes . chamber lens implantation for the correction Retinal detachment following anterior
The development of retinal detachment is reported in three eyes, of two patients, following implantation of an anterior chamber intraocular lens (AC-IOL) in phakic eyes for the correction of ultra-high myopia. The presence ofan AC-IOL may hamper the identification of retinal breaks and removal of the intraocular lens may prove necessary to improve visualisation. Shallowing of the anterior chamb...
متن کاملOPTH-5710-Phakic anterior chamber intraocular lens - Verisyse
Correspondence: Amir Pirouzian 710 Lawerence Expressway, Dept 490, Santa Clara, CA 95051, USA Tel +1 408 851 4100 Email [email protected] Purpose: The current study aims to evaluate both safety and efficacy of VerisyseTM (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (-8 D) myopic anisometropia in children who are noncompliant to...
متن کاملPhakic anterior chamber intraocular lens (Verisyse™) implantation in children for treatment of severe ansiometropia myopia and amblyopia: Six-month pilot clincial trial and review of literature
PURPOSE The current study aims to evaluate both safety and efficacy of Verisyse() (AMO, Irvine, CA) phakic anterior chamber intraocular lens (IOL) in the reduction of clinically significant (>-8 D) myopic anisometropia in children who are noncompliant to traditional medical treatment including spectacle correction or contact lenses. DESIGN Retrospective interventional case series. METHODS S...
متن کاملAnterior chamber iris-fixated phakic intraocular lens for anisometropic amblyopia.
We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...
متن کامل