Reproducibility of optic disk evaluation in supine subjects with a Heidelberg Retina Tomograph II laser tomographic scanner

نویسندگان

  • Yosuke Harada
  • Tomoyuki Akita
  • Joji Takenaka
  • Yuko Nakamura-Kadohiro
  • Junko Tanaka
  • Yoshiaki Kiuchi
چکیده

AIM The aim of this study was to determine the reproducibility and reliability of optic disk evaluation in supine subjects with a Heidelberg Retina Tomograph II (HRT II). METHODS One eye was randomly selected for evaluation by HRT II in each of eleven healthy subjects. Five images were obtained by each of two experienced operators at two separate visits with the subjects in both sitting and supine positions. A stand was constructed to allow stable, handheld operation of the HRT II head for imaging of the supine subjects. Measurements of optic disk parameters obtained in the supine position were compared with those obtained in the sitting position. The reliability of measurements in the supine position was evaluated by calculating both the coefficients of variation for measurements made by one observer on the first visit and the interobserver and intervisit intraclass correlation coefficients (ICCs); the values obtained were compared with those obtained for the sitting position. RESULTS Measurements of all parameters made in the supine position were highly similar to those made in the sitting position. The coefficients of variation obtained for each parameter in the sitting and supine positions ranged from 5.67% to 14.16% and from 2.18% to 16.08%, respectively. The interobserver ICC values in the sitting and supine positions were ≥0.978 and ≥0.989, respectively. The intervisit ICC values in the sitting and supine positions were ≥0.958 and ≥0.983, respectively. CONCLUSION Handheld operation of the HRT II in a custom-designed stand is feasible for optic disk evaluation in the supine subjects who were not able to maintain the sitting position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of optic disc topography measured by Retinal Thickness Analyzer with measurement by Heidelberg Retina Tomograph II.

PURPOSE To compare the optic disc topography measurements from a digitized laser slit-lamp and a confocal scanning laser ophthalmoscope (SLO). METHODS Ten normal subjects (10 eyes) were recruited. Topographic measurements of the optic disc were performed three times in all eyes using the Retinal Thickness Analyzer (RTA) and the Heidelberg Retina Tomograph II (HRT II), and the mean values dete...

متن کامل

Comparison between Optic Nerve Head Topography – Using the Heidelberg Retina Tomograph – and Resolution Visual Fields

Early diagnosis is probably essential for the outcome of glaucoma treatment, and a number of methods for detecting glaucomatous damage have been developed and evaluated1. Resolution perimetry (HRP)2,3, measuring spatial resolution, is one of the methods with the highest sensitivity1. It has been found to be reliable and useful in the management and follow-up of glaucoma4-10. Another way of dete...

متن کامل

Comparison between laser scanning tomography and computerised image analysis of the optic disc.

AIMS To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. METHODS One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidel...

متن کامل

Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

AIMS The Heidelberg retina tomograph (HRT) is a scanning laser ophthalmoscope with confocal optics. The reproducibility of the optic nerve head topography is accurate and reliable. The authors describe a new technique for the assessment of macular thickening by volumetric quantification and present the results of its reproducibility in normal subjects. METHODS Topographic images of the macula...

متن کامل

Ultrasonographic evaluation of optic disc swelling: comparison with CSLO in idiopathic intracranial hypertension.

PURPOSE To determine the accuracy and reproducibility of ultrasonographic (US) readings of optic disc elevations in patients with papilledema compared with confocal scanning laser ophthalmoscope (CSLO) measurements. METHODS One randomly selected eye of 22 patients with idiopathic intracranial hypertension (IIH) and a variable degree of optic disc swelling underwent five and three repeated mea...

متن کامل