Refinements in stress echocardiographic techniques improve inter-institutional agreement in interpretation of dobutamine stress echocardiograms.

نویسندگان

  • R Hoffmann
  • T H Marwick
  • D Poldermans
  • H Lethen
  • R Ciani
  • P van der Meer
  • H-P Tries
  • P Gianfagna
  • P Fioretti
  • J J Bax
  • M A Katz
  • R Erbel
  • P Hanrath
چکیده

AIMS To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echocardiographic technology in combination with standardized data acquisition and assessment criteria. METHOD AND RESULTS Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 microg x kg(-1) min(-1) and atropine up to 1 mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (> or = 50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5+/-0.8 institutions) or three-vessel coronary artery disease (5.4+/- 0.8 institutions) and lower in one- or two- vessel disease (5.0+/-0.9 and 5.2+/-1.0 institutions, respectively; P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P<0.01 vs harmonic imaging). CONCLUSION Modern echocardiographic technology in combination with standardized digital image processing and uniform reading criteria results in a higher inter-institutional agreement in the interpretation of dobutamine stress echocardiogram compared to historic reports.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The demystification of magnetic resonance imaging?

The interobserver variability in test interpretation is a key parameter to evaluate the diagnostic reliability of a diagnostic examination. It has been evaluated for most clinically relevant cardiac imaging modalities. In many instances the results have been rather sobering. A considerable variability in the visual assessment of coronary artery stenosis severity has been shown between different...

متن کامل

Improved interpretation of dobutamine stress echocardiography following 4 months of systematic training in patients following acute myocardial infarction.

OBJECTIVES Interpretation of stress echocardiography is subjective, and highly dependent on the experience of the interpreter. We sought to evaluate whether a cardiologist without any previous experience in stress echocardiography could adequately learn the skills of interpreting dobutamine stress echocardiograms (DSE) in post-infarct patients, after a period of systematic training. METHODS A...

متن کامل

Can we quantify ischaemia during Dobutamine stress echocardiography in clinical practice?

Dobutamine stress echocardiography (DSE) is an accurate non-invasive technique for detecting coronary artery disease and is a test which has significant prognostic value in clinical practice, both in detecting viability and in risk stratification. However, the current clinical implementation of the technique is based solely on the visual detection of ischaemia-induced radial wall motion abnorma...

متن کامل

Coronary Artery Spasm During Dobutamine Stress Echocardiography: A Case Report

Dobutamine stress echocardiography (DSE) has been widely used as a diagnostic and prognostic modality in the management of stress. DSE is associated with limited complications and adverse effects on the health of patients. In this case report, we described a 42-year-old female patient with dobutamine-induced coronary artery spasm with history of exertional dyspnea, which had deteriorated recent...

متن کامل

Echocardiographic detection of coronary artery disease during dobutamine infusion.

BACKGROUND Two-dimensional echocardiography performed during dobutamine infusion has been proposed as a potentially useful method for detecting coronary artery disease. However, the safety and diagnostic value of dobutamine stress echocardiography has not been established. METHODS AND RESULTS In this study, echocardiograms were recorded during step-wise infusion of dobutamine to a maximum dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 2002