Tolerance limits for short-term analytical bias and analytical imprecision derived from clinical assay specificity.

نویسنده

  • G G Klee
چکیده

I propose a method for defining tolerance limits for assay bias and assay imprecision, based on the effects of these tolerance limits on the clinical specificity of the assay. An analytical "error budget" is defined as the squared sums of the imprecision and bias errors. The maximum limit for this error budget is set at a value corresponding to a 50% increase in the false-positive rate for classifying healthy subjects. For gaussian distributions with +/- 2 SD used as decision limits, this error budget equates to 0.45 SD of combined within-person and between-person biological variation (SDBiol). To provide reasonable power for bias detection in an assay, I recommend that the SD of the assay be kept at less than half the bias limit. Then, for the gaussian distribution, the maximum bias limit should be < 0.36 SDBiol and the SD of the assay should be < 0.18 SDBiol. Procedures are provided for using the same principles to define tolerance limits for decision limits other than +/- 2 SD and for nongaussian distributions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance goals for the laboratory testing of antithrombin, protein C and protein S.

To achieve a reliable analytical quality for both monitoring and diagnostic testing, laboratories need to fulfil the widely accepted analytical performance goals based on the biological variation of the analytes of testing. Not only is the short-term analytical performance, which regularly is assessed by internal quality control procedures, of importance, but also the long-term analytical perfo...

متن کامل

Analytical goal-setting for monitoring patients when two analytical methods are used.

Serial results from an individual are often obtained using more than one method. Results should be transferable over time and locale. Every method has inherent analytical error, and goals are required to delineate the maximum allowable random (imprecision) and systematic (inaccuracy, bias) errors to facilitate optimal patient care. Based on Harris's proposal [Am J Clin Pathol 1979;72:374-82] th...

متن کامل

Setting performance goals and evaluating total analytical error for diagnostic assays.

BACKGROUND Total analytical error has been a useful metric both to assess laboratory assay quality and to set goals. It is often estimated by combining imprecision (SD) and average bias in the equation: total analytical error = bias + 1.65 x imprecision. This indirect estimation model (referred to as the simple combination model) leads to different estimates of total analytical error than that ...

متن کامل

The significance of reporting to the thousandths place: Figuring out the laboratory limitations

OBJECTIVES A request to report laboratory values to a specific number of decimal places represents a delicate balance between clinical interpretation of a true analytical change versus laboratory understanding of analytical imprecision and significant figures. Prostate specific antigen (PSA) was used as an example to determine if an immunoassay routinely reported to the hundredths decimal place...

متن کامل

Diagnostic performance of the ARCHITECT C-Peptide immunoassay.

BACKGROUND Measurement of C-peptide under standardized conditions provides a sensitive and well-established assessment of beta-cell function. We describe the analytical and clinical validation of an automated, microparticle-based chemiluminescent immunoassay method. The assay is designed to measure C-peptide in human serum, plasma and urine. METHODS Assay performance characteristics such as p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 7  شماره 

صفحات  -

تاریخ انتشار 1993