A high-temperature liquid chromatographic reactor approach for investigating the solvolytic stability of a pharmaceutical compound and an investigation of its retention behavior on a C18-modified zirconia stationary phase.

نویسندگان

  • Peter J Skrdla
  • Angela Bopra
  • Tyson Chasse
  • Tao Wang
چکیده

The solvolysis kinetics of a developmental active pharmaceutical ingredient (API) were investigated using a high temperature (HT)-HPLC reactor approach to determine whether it might be possible to use the technique to efficiently screen the relative stabilities of typical APIs (particularly those that are stable at the column temperatures achievable on most HPLC systems and over durations of less than 60 min-a reasonable upper limit for typical method run time). It was discovered that the on-column API degradation kinetics better obeyed a second-order model than a first-order one. Employing a newly developed mathematical treatment, the apparent activation energy for the process was determined to be 85.7+/-1.6 kJ/mol; the apparent frequency factor was found to be (3.9+/-0.4)x10(4) s(-1). The retention mechanism of the API on the C18-modified zirconia column (ZirChrom) Diamondbond-C18) was investigated using a van't Hoff analysis. It was discovered that the logarithm of the retention factor (following correction for the gradient elution of the assay method) exhibited a quadratic dependence on the reciprocal of the absolute temperature. While the retention was found to be predominantly enthalpically driven over the majority of temperatures investigated in this study (ranging from 40 to 200 degrees C), a regression fit of the curve predicted a maximum at approximately 20 degrees C, indicative of a transition from predominantly enthalpically controlled retention to a mainly entropically driven mechanism. A table summarizing the thermodynamic retention parameters at each experimental column temperature is provided. Finally, the preliminary application of the HT-HPLC reactor approach to the study of degradation kinetics of other APIs is discussed in terms of some unexpected findings obtained using the zirconia column.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2008