Biomechanics of the Cornea Evaluated by Spectral Analysis of Waveforms from Ocular Response Analyzer and Corvis-ST
نویسندگان
چکیده
PURPOSE In this study, spectral analysis of the deformation signal from Corvis-ST (CoST) and reflected light intensity from ocular response analyzer (ORA) was performed to evaluate biomechanical concordance with each other. METHODS The study was non-interventional, observational, cross-sectional and involved 188 eyes from 94 normal subjects. Three measurements were made on each eye with ORA and CoST each and then averaged for each device. The deformation signal from CoST and reflected light intensity (applanation) signal from ORA was compiled for all the eyes. The ORA signal was inverted about a line joining the two applanation peaks. All the signals were analyzed with Fourier series. The area under the signal curves (AUC), root mean square (RMS) of all the harmonics, lower order (LO included 1st and 2nd order harmonic), higher order (HO up to 6th harmonic), CoST deformation amplitude (DA), corneal hysteresis (CH) and corneal resistance factor (CRF) were analyzed. RESULTS The device variables and those calculated by Fourier transform were statistically significantly different between CoST and ORA. These variables also differed between the eyes of the same subject. There was also statistically significant influence of eyes (left vs. right) on the differences in a sub-set of RMS variables only. CH and CRF differed statistically significantly between the eyes of subject (p<0.001) but not DA (p = 0.65). CONCLUSIONS CoST was statistically significantly different from ORA. CoST may be useful in delineating true biomechanical differences between the eyes of a subject as it reports deformation.
منابع مشابه
Erratum: A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST
OBJECTIVE To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST. SETTING AND DESIGN Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012. METHODS One hundred and t...
متن کاملCorneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications
BACKGROUND Ectasia development occurs due to a chronic corneal biomechanical decompensation or weakness, resulting in stromal thinning and corneal protrusion. This leads to corneal steepening, increase in astigmatism, and irregularity. In corneal refractive surgery, the detection of mild forms of ectasia pre-operatively is essential to avoid post-operative progressive ectasia, which also depend...
متن کاملThe mystery of collagen cross-linking when it comes to in vivo biomechanical measurements.
To the Editor: Bak-Nielsen et al. recently reported on the dynamic assessment of keratoconus and the effects of corneal cross-linking (CXL).1 The authors described the corneal deformation during rapidly applied force via an air jet using ultra high-speed Scheimpflug technology (Corvis ST; Oculus Optikgeräte GmbH, Wetzlar, Germany).1 Patients with both untreated and CXL-treated keratoconus were ...
متن کاملOcular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.
AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any...
متن کاملEditorial: Update on Glaucoma Diagnosis and Management.
Glaucoma is one of the most dreadful ocular conditions that affects millions of people worldwide and is one of the major causes of irreversible blindness. Although glaucoma is a complex and poorly understood disorder, the primary goal of therapy is lowering Intraocular Pressure (IOP), which is not only one of the most significant risk factors in development of the disease, but also the only mod...