In‐house quality check of external beam plans using 3D treatment planning systems — a DVH comparison

نویسندگان

  • Ayyalasomayajula Anil Kumar
  • Roopa Rani Akula
  • Komanduri Ayyangar
  • Reddy P. Krishna
  • Srinivas Vuppu
  • P. V. Lakshmi Narayana
  • A. Durga Prasada Rao
چکیده

This paper presents a new approach towards the quality assurance of external beam plans using in-house-developed DICOM import and export software in a clinical setup. The new approach is different from what is currently used in most clinics, viz., only MU and point dose are verified. The DICOM-RT software generates ASCII files to import/export structure sets, treatment beam data, and dose-volume histo-grams (DVH) from one treatment planning system (TPS) to the other. An efficient and reliable 3D planning system, ROPS, was used for verifying the accuracy of treatment plans and treatment plan parameters. With the use of this new approach, treatment plans planned using Varian Eclipse planning system were exported to ROPS planning system. Important treatment and dosimetrical data, such as the beam setup accuracy, target dose coverage, and dose to critical structures, were also quantitatively verified using DVH comparisons. Two external beam plans with diverse photon energies were selected to test the new approach. The satisfactory results show that the new approach is feasible, easy to use, and can be used as an adjunct test for patient treatment quality check.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

External radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans

Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...

متن کامل

Equivalent‐quality unflattened photon beam modeling, planning, and delivery

The clinical application of the flattening filter-free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high-dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of mode...

متن کامل

3D Analysis of Intensity-Modulated Radiation Therapy Quality Assurance Measurement using a 2D Diode Array

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commer...

متن کامل

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

Evaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016